16 Technical Data
SMA Solar Technology AG
Operating Manual
STPx0-3SE-40-BE-en-10
122
16 Technical Data
AC terminal
STP5.0-3SE-40
STP6.0-3SE-40
STP8.0-3SE-40
STP10.0-3SE-40
Rated power at
230 V, 50 Hz
5000 W
6000 W
8000 W
10000 W
Maximum appar-
ent power at
cos φ = 1
5000 VA
6000 VA
8000 VA
10000 VA
Rated apparent
power at
cos φ = 1
5000 VA
6000 VA
8000 VA
10000 VA
Nominal grid volt-
age
3/N/grounding
conductor;
220 V / 380 V
3/N/grounding
conductor;
230 V / 400 V
3/N/grounding
conductor;
240 V / 415 V
3/N/grounding
conductor;
220 V / 380 V
3/N/grounding
conductor;
230 V / 400 V
3/N/grounding
conductor;
240 V / 415 V
3/N/grounding
conductor;
220 V / 380 V
3/N/grounding
conductor;
230 V / 400 V
3/N/grounding
conductor;
240 V / 415 V
3/N/grounding
conductor;
220 V / 380 V
3/N/grounding
conductor;
230 V / 400 V
3/N/grounding
conductor;
240 V / 415 V
Rated grid voltage
230 V
230 V
230 V
230 V
Voltage range
156 V to 277 V
156 V to 277 V
156 V to 277 V
156 V to 277 V
Rated current at
230 V
3 x 7.3 A
3 x 8.7 A
3 x 11.6 A
3 x 14.5 A
Maximum output
current
3 x 7.6 A
3 x 9.1 A
3 x 12.1 A
3 x 15.2 A
Maximum input
power for backup
loads in parallel
grid operation
13800 W
13800 W
13800 W
13800 W
Maximum input
current for backup
loads in parallel
grid operation
3 x 20 A
3 x 20 A
3 x 20 A
3 x 20 A
Rated grid fre-
quency
50 Hz
50 Hz
50 Hz
50 Hz
Operating range
at grid frequency
50 Hz
45 Hz to 55 Hz
45 Hz to 55 Hz
45 Hz to 55 Hz
45 Hz to 55 Hz