SMA
Technologie AG
Unit description
Operating instructions
WB11_17-11:FE4205
Page 27
Display message during operation
The display shows the most important operational information of the Windy Boy in a
continuous cycle. The following three diagrams serve to clarify the messages. Every
message is displayed for 5 seconds. Then the cycle begins again
.
The energy generated today and the current opera-
tional status are first displayed.
Subsequently, the current feed-in power and the out-
put voltage are displayed.
This is then followed by the total energy produced so
far and the operational hours of the device.
Fault displays
If an operational fault develops, the display immedi-
ately switches to "Disturbance" and the background
illumination is switched on.
The cause of the fault is displayed for 5 seconds in
the second line of the display.
If
a measured value is responsible for the fault condi-
tion, then the value measured at the time of the fault
is displayed. If another measurement is possible, the
current value is displayed in the second line.
After another 5 seconds, normal operational information is again displayed.
If the fault is still present, the fault display starts again from the beginning. An over-
view of the status and fault messages can be found in chapter 9.2 "Fault messages”
(page 58) of this document.
Note: The amount of energy shown under "E-today" does not necessarily
reflect the amount of energy produced over the last 24 hours. This is rath-
er the energy produced by the Windy Boy since the last deactivation/ac-
tivation (wind turbine standstill).
Energy sum since the last activation, and
the current operational status
E-today 3.86
Status Turbine
Current feed-in power and
AC voltage
Pac 903W
Vac 195V
Total amount of energy produced and the
total number of operating hours
E-total 724,4kWh
h-total 512h
Fault display
Disturbance
Vac-Bfr
Display of the values measured
during the fault
at: 261V
present: 245V
Summary of Contents for Windy Boy 1100
Page 2: ......
Page 4: ...SMA Technologie AG Page 4 WB11_17 11 FE4205 Operating Instructions...
Page 12: ...Safety Information SMA Technologie AG Page 12 WB11_17 11 FE4205 Operating instructions...
Page 36: ...Turbine operation SMA Technologie AG Page 36 WB11_17 11 FE4205 Operating instructions...
Page 38: ...Maintenance and care SMA Technologie AG Page 38 WB11_17 11 FE4205 Operating instructions...
Page 64: ...Stand alone systems SMA Technologie AG Page 64 WB11_17 11 FE4205 Operating instructions...
Page 66: ...Contact SMA Technologie AG Page 66 WB11_17 11 FE4205 Operating instructions...
Page 67: ......