Technical data
SMA
Technologie AG
Page 48
WB11_17-11:FE4205
Operating instructions
8.1.2 Grid connection data
Nominal output power
P
ACnom
1000 W
Peak output power
P
ACmax
1100 W
Nominal output current
I
ACnom
4.4 A
Harmonic distortion of output
current
THD
IAC
< 4 % (P
AC
> 0.5 P
ACnom
)
Operating range, grid voltage
U
AC
198 ... 260 V AC
(180 ... 265 V programmable)
Operating range, grid frequen-
cy
f
AC
49.8 ... 50.2 Hz / 59.8 ... 60.2 Hz
(45.5 ... 54.5 Hz / 55.5 ... 64.5 Hz
programmable)
All-pole isolator grid side
Independent disconnection device
(SMA grid guard)
Phase shift angle
(relative to the fundamental
wave of the current)
cos Phi
1
Overvoltage category
III
Test voltage (50 Hz)
1.4 kV (1 s routine testing / 5 s type
testing)
Test surge voltage
4 kV (1.2/50 ms)
(serial interface: 6 kV)
Own consumption in standby
mode
0.1 W