8 Technical data
8.1 Windy Boy 1100
8.1.1 DC connection data
Max. input open circuit voltage U
DC 0
400 V
Input voltage, MPP range
U
DC
139 V ... 400 V DC
Nominal DC operating voltage
U
DC nom
180 V
Max. input current
I
DC max
10 A
Max. input power
P
DC
max
1210 W
Recommended generator pow-
er at 5000 full-load hours / year
P
turb max
800 W
Recommended generator pow-
er at 2500 full-load hours / year
P
turb max
900 W
All-pole isolator on the DC input
side
DC plug connector
Overvoltage protection
Thermally monitored varistors
DC voltage ripple
U
SS
< 10 % of the input voltage
Personal protection
Insulation monitoring (Riso > 1 M
Ω
)
Operating consumption
< 5 W (standby)
Reverse polarity protection
Short circuit diode