SMA
Technologie AG
Technical data
Operating instructions
WB11_17-11:FE4205
Page 49
8.1.3 General data
For a detailed description of the device, see chapter 3 "Unit description” (page 13)
of this manual.
The efficiency of the Windy Boy is heavily dependent on the DC input voltage. The
lower the input voltage the higher is the efficiency.
General data
Protection type to DIN EN 60529
IP65
External temperature range
-25° C to +60° C
Dimensions (w x h x d)
322 mm x 320 mm x 180 mm
Weight
21 kg (approx.)
External interfaces
Data transfer (mains cable)
Optional
Data transfer (data cable)
Optional, RS232 / RS485
Data transfer (wireless)
Optional
Efficiency
Max. efficiency
η
max
> 93,0 %
85
0
200
400
300
100
500
700
600
84
86
87
88
89
90
91
92
93
94
Output power [W]
Ov
erall ef
ficiency [%
]
800
900
1000 1100
Windy Boy 1100