Technical data
SMA
Technologie AG
Page 50
WB11_17-11:FE4205
Operating instructions
8.2 Windy Boy 1700
8.2.1 DC connection data
Max. input open circuit voltage
U
DC 0
400 V
Input voltage, MPP range
U
DC
139 V ... 400 V DC
Nominal DC operating voltage
U
DC nom
180 V
Max. input current
I
DC max
12.6 A
Max. input power
P
DC max
1850 W
Recommended generator power
at 5000 full-load hours / year
P
turb max
1240 W
Recommended generator power
at 2500 full-load hours / year
P
turb max
1395 W
All-pole isolator on
the DC input side
DC plug connector
Overvoltage protection
Thermally monitored varistors
Voltage ripple
U
PP
< 4 % of the input voltage
Personal protection
Insulation monitoring (Riso > 1 M
Ω
)
Operating consumption
< 4 W
Reverse polarity protection
Short circuit diode