SMA
Technologie AG
Technical data
Operating instructions
WB11_17-11:FE4205
Page 51
8.2.2 Grid connection data
Nominal output power
P
ACnom
1550 W
Peak output power
P
ACmax
1700 W
Nominal output current
I
ACnom
6.5 A
Harmonic distortion of output cur-
rent (at K
Unom
< 2 %,
P
AC
> 0.5 P
ACnom
)
THD
IAC
< 4 %
Operating range, grid voltage
V
AC
198 ... 260 V AC
(180 ... 265 V programmable)
Operating range, grid frequency f
AC
49.8 ... 50.2 Hz / 59.8 ... 60.2 Hz
(45.5 ... 54.5 Hz / 55.5 ... 64.5 Hz
programmable)
All-pole isolator grid side
Independent disconnection device
(SMA grid guard)
Phase shift angle
(relative to the fundamental wave
of the current)
cos
ϕ
1
Overvoltage category
III
Test voltage (50 Hz)
1.4 kV (1 s routine testing / 5 s type
testing)
Test surge voltage
4 kV (1.2/50 ms)
(serial interface: 6 kV)
Own consumption in standby
mode
0.1 W
Summary of Contents for Windy Boy 1100
Page 2: ......
Page 4: ...SMA Technologie AG Page 4 WB11_17 11 FE4205 Operating Instructions...
Page 12: ...Safety Information SMA Technologie AG Page 12 WB11_17 11 FE4205 Operating instructions...
Page 36: ...Turbine operation SMA Technologie AG Page 36 WB11_17 11 FE4205 Operating instructions...
Page 38: ...Maintenance and care SMA Technologie AG Page 38 WB11_17 11 FE4205 Operating instructions...
Page 64: ...Stand alone systems SMA Technologie AG Page 64 WB11_17 11 FE4205 Operating instructions...
Page 66: ...Contact SMA Technologie AG Page 66 WB11_17 11 FE4205 Operating instructions...
Page 67: ......