9.1.2 Windy Boy operating parameters
Unauthorized changes to the operating parameters may result in:
• Injury or accidents as a result of changing the internal safety
routines in the Windy Boy,
• Voiding the Windy Boy's operating approval certificate,
• Voiding the Windy Boy's guarantee
Never change the parameters of your Windy Boy without explicit
authorization and instructions.
Name
Unit
Value range
(WB 1100 /
WB 1700)
Factory
settings
(WB 1100 /
WB 1700)
Description
Betriebsart /
Operating
Mode
MPP
UKonst
Stop
Turbine Mode
Turbine
Operating mode of the Windy Boy
MPP: Maximum Power Point
UKonst: Constant voltage mode
(Desired voltage is defined in "Usoll-
Konst")
Stop: Disconnection from mains
network, no operation
Turbine: Operating mode for wind
turbines, the input voltage is converted
according to the V/I function defined
by U
PV
Start, U
DC
WindStart and
U
DC
WindMax.
Default
GER/ENS
Used for setting the country specific
information.
dFac-MAX
Hz/s
0.005 ... 4.0
0.25
Maximum "Mains frequency change"
before the mains monitoring system
disconnects the device from the mains
supply.
dZac-MAX
mOhm
0 ... 20000
350
Maximum "Mains impedance change"
before the mains monitoring system
disconnects the device from the mains
supply.
E_Total
kWh
0 ... 200000
Total energy yield (E_Total) and total
hours of operation (h_Total) for the
inverter. This change may be necessary
when you exchange your Windy Boy
and want to use the data from the old
device.
h_Total
h
0 ... 200000
Fac-delta-
Hz
0 ... 4.5
0.19
Maximum frequency, above (Fac-
Delta+) and below (Fac-Delta-) the
mains frequency of 50 Hz, before the
mains monitoring system disconnects
the device from the mains supply.
Fac-delta+
Hz
0 ... 4.5
0.19
Summary of Contents for Windy Boy 1100
Page 2: ......
Page 4: ...SMA Technologie AG Page 4 WB11_17 11 FE4205 Operating Instructions...
Page 12: ...Safety Information SMA Technologie AG Page 12 WB11_17 11 FE4205 Operating instructions...
Page 36: ...Turbine operation SMA Technologie AG Page 36 WB11_17 11 FE4205 Operating instructions...
Page 38: ...Maintenance and care SMA Technologie AG Page 38 WB11_17 11 FE4205 Operating instructions...
Page 64: ...Stand alone systems SMA Technologie AG Page 64 WB11_17 11 FE4205 Operating instructions...
Page 66: ...Contact SMA Technologie AG Page 66 WB11_17 11 FE4205 Operating instructions...
Page 67: ......