SMA
Technology AG
General information
Operating instructions
WB50_60-11:FE4105
Page 59
The following parameters are displayed in the parameter list but cannot be modified:
U
DC
WindStart
V
1 ... 800
330
U
DC
WindStart represents the lowest
point of the function (please read more
about this topic in chapter 6 "Turbine
operation” (page 33)). (only possible in
Turbine mode!)
Usoll-Konst /
Vconst-
Setpiont
V
250
...600
600
Desired DC voltage for constant
operational voltage. These parameters
are only important when the
"Betriebsart" parameter is set to U-
Konst.
U
PV
Start
V
250 ... 600
300
U
PV
Start is the parameter defining the
voltage at which the Windy Boy is
capable of connecting to the system.
180 V is the recommended voltage for
the Windy Boy 5000 and the Windy
Boy 6000. Reducing this voltage
parameter can lead to numerous
unnecessary connection attempts.
Increasing this voltage parameter can
lead to energy losses since the Windy
Boy does not immediately connect to the
system.
Name
Unit
Value range
(WB5000/
6000)
Factory
settings
(WB5000/
6000)
Description
Plimit
W
5000 / 6000
5000 / 6000
Upper limit for AC output power
SMA-SN
Serial number of the Windy Boy 5000
/ 6000
Software-BFR /
Firmware-BFR
Firmware version of the operation
control unit (BFR)
Software-SRR /
Firmware-SRR
Firmware version of the current control
unit (SRR)
Name Unit
Value
range
(WB 5000 /
WB 6000)
Factory
settings
(WB 5000
/WB
6000)
Description
Summary of Contents for Windy Boy 5000
Page 2: ......
Page 4: ...SMA Technologie AG Page 4 WB50_60 11 FE4105 Operating Instructions ...
Page 12: ...Safety information SMA Technology AG Page 12 WB50_60 11 FE4105 Operating instructions ...
Page 28: ...Unit description SMA Technology AG Page 28 WB50_60 11 FE4105 Operating instructions ...
Page 32: ...Maintenance and care SMA Technology AG Page 32 WB50_60 11 FE4105 Operating instructions ...
Page 38: ...Turbine operation SMA Technology AG Page 38 WB50_60 11 FE4105 Operating instructions ...
Page 40: ...Maintenance and care SMA Technology AG Page 40 WB50_60 11 FE4105 Operating instructions ...
Page 66: ...Stand alone systems SMA Technology AG Page 66 WB50_60 11 FE4105 Operating instructions ...
Page 68: ...Contact SMA Technology AG Page 68 WB50_60 11 FE4105 Operating instructions ...
Page 69: ......