SMA
Technology AG
Technical data
Operating instructions
WB50_60-11:FE4105
Page 49
9 Technical data
9.1 Windy Boy 5000
9.1.1 DC connection data
Max. input open circuit voltage
V
DC 0
600 V
Input voltage, MPP range
V
DC
246 V ... 600 V DC
Nominal DC operating voltage
V
DC nom
270 V
Max. input current
I
DC max
26 A
Max. input power
P
DC max
5750 W
Recommended generator power
at 5,000 full-load hours / year
P
turb max
4000 W
Recommended generator power
at 2,500 full-load hours / year
P
turb max
4500 W
All-pole isolator on the DC input
side
DC plug connector
Overvoltage protection
Thermally monitored varistors
DC voltage ripple
U
SS
< 10% of the input voltage
Personal protection
Insulation monitoring (Riso > 1 M
Ω
)
Own consumption in standby
mode
< 7 W (standby)
Reverse polarity protection
Short circuit diode
Summary of Contents for Windy Boy 5000
Page 2: ......
Page 4: ...SMA Technologie AG Page 4 WB50_60 11 FE4105 Operating Instructions ...
Page 12: ...Safety information SMA Technology AG Page 12 WB50_60 11 FE4105 Operating instructions ...
Page 28: ...Unit description SMA Technology AG Page 28 WB50_60 11 FE4105 Operating instructions ...
Page 32: ...Maintenance and care SMA Technology AG Page 32 WB50_60 11 FE4105 Operating instructions ...
Page 38: ...Turbine operation SMA Technology AG Page 38 WB50_60 11 FE4105 Operating instructions ...
Page 40: ...Maintenance and care SMA Technology AG Page 40 WB50_60 11 FE4105 Operating instructions ...
Page 66: ...Stand alone systems SMA Technology AG Page 66 WB50_60 11 FE4105 Operating instructions ...
Page 68: ...Contact SMA Technology AG Page 68 WB50_60 11 FE4105 Operating instructions ...
Page 69: ......