4.3.2 Critical Faulty Operation
A comprehensive safety concept has limited the number of critical conditions that can
occur to one single situation:
Input voltage exceeds the permitted value!
This is indicated by the following blink code on the yellow LED:
The yellow fault LED illuminates for 5 seconds when this fault occurs, then begins
displaying the blink code of: 3 seconds off, then 4 times briefly on. This code is
displayed 3 times in succession. If the fault is still present, the fault display starts again
from the beginning.
The presence of excessive input voltage can lead to irreparable damage!
Immediately disconnect the Windy Boy's DC input.
When the Windy Boy receives an excessive DC input voltage, it automatically
disconnects from the grid and ceases its power feeding activity. When the Windy
Boy is in operation, you must always first disconnect the AC voltage (grid voltage)
and only then should you disconnect the DC voltage from the Windy Boy!
The yellow LED illuminates 4
times in quick succession
The code is repeated 3
times, then begins again.
LED on
LED off
(green)
(red)
(yellow)
Summary of Contents for Windy Boy WB 1100LV
Page 2: ......
Page 6: ...Explanation of Symbols Used SMA Technologie AG Page 6 WB1100LV 11 FE2606 User Manual...
Page 10: ...Safety Instructions SMA Technologie AG Page 10 WB1100LV 11 FE2606 User Manual...
Page 28: ...Unit Description SMA Technologie AG Page 28 WB1100LV 11 FE2606 User Manual...
Page 30: ...Setting the Display Language SMA Technologie AG Page 30 WB1100LV 11 FE2606 User Manual...
Page 40: ...Turbine Operation SMA Technologie AG Page 40 WB1100LV 11 FE2606 User Manual...
Page 42: ...Maintenance and Care SMA Technologie AG Page 42 WB1100LV 11 FE2606 User Manual...
Page 50: ...Extensions SMA Technologie AG Page 50 WB1100LV 11 FE2606 User Manual...
Page 54: ...Technical Data SMA Technologie AG Page 54 WB1100LV 11 FE2606 User Manual...
Page 72: ...General Information SMA Technologie AG Page 72 WB1100LV 11 FE2606 User Manual...
Page 74: ...Stand Alone Systems SMA Technologie AG Page 74 WB1100LV 11 FE2606 User Manual...
Page 77: ......