Technical Data
SMA
Technologie AG
Page 52
WB1100LV-11:FE2606
User Manual
9.2 Grid Connection Data
Description
Short
descr.
Setting
Nominal output power
P
ACnom
1000 W
Continuous output power
(at 45°C)
1000 W
Nominal output current
I
ACnom
4.4 A
Harmonic distortion of output
current (at K
Ugrid
< 2 %, P
AC
>
0.5 P
ACnom
)
THD
< 4 %
Short-circuit proofing
grid-side via current regulation
Operating range, grid voltage
U
AC
180 ... 265 V AC
Germany: 198 ... 253 / 260 V AC
a
Operating range, grid frequency
f
AC
45.5 ... 54.5 Hz
Germany: 47.55 ... 50.2 Hz
All-pole isolator
on grid side
automatic disconnection device ("SMA
grid guard 2"), double implementation
Power factor (based on the
current's fundamental frequency)
cos phi
1
Overvoltage category
III
Test voltage (DC)
1.6 kV (1 s routine testing / 5 s type
testing)
Test surge voltage
4 kV (serial interface: 6 kV)
Operating consumption in night
mode
0.1 W
a
The Windy Boy can feed into the public grid at a maximum output voltage of
260 V for brief periods. However, DIN VDE 0126-1-1 stipulates that the 10-
minute average must not exceed a voltage of 253 V. That means, if the grid
voltage is constantly 254 V (e.g.), the inverter disconnects itself from the grid.
In this case, contact the local grid operator for assistance.
DIN VDE 0126-1-1 only applies in Germany. See section 10.1.5 "Country-
Specific Parameter Settings" (Page 62) for all other preset country values of
your inverter.
Summary of Contents for Windy Boy WB 1100LV
Page 2: ......
Page 6: ...Explanation of Symbols Used SMA Technologie AG Page 6 WB1100LV 11 FE2606 User Manual...
Page 10: ...Safety Instructions SMA Technologie AG Page 10 WB1100LV 11 FE2606 User Manual...
Page 28: ...Unit Description SMA Technologie AG Page 28 WB1100LV 11 FE2606 User Manual...
Page 30: ...Setting the Display Language SMA Technologie AG Page 30 WB1100LV 11 FE2606 User Manual...
Page 40: ...Turbine Operation SMA Technologie AG Page 40 WB1100LV 11 FE2606 User Manual...
Page 42: ...Maintenance and Care SMA Technologie AG Page 42 WB1100LV 11 FE2606 User Manual...
Page 50: ...Extensions SMA Technologie AG Page 50 WB1100LV 11 FE2606 User Manual...
Page 54: ...Technical Data SMA Technologie AG Page 54 WB1100LV 11 FE2606 User Manual...
Page 72: ...General Information SMA Technologie AG Page 72 WB1100LV 11 FE2606 User Manual...
Page 74: ...Stand Alone Systems SMA Technologie AG Page 74 WB1100LV 11 FE2606 User Manual...
Page 77: ......