SMA
Technologie AG
General Information
User Manual
WB1100LV-11:FE2606
Page 67
UpvMax
Overvoltage at DC input.
Immediately disconnect the DC input of the Windy Boy.
Otherwise the Windy Boy could be severely damaged!
Check the configuration of your system and measure the DC voltage
before reconnecting the Windy Boy to the DC voltage.
Watchdog
Error message in the program code flow monitoring.
Zac-Bfr /
Zac-Srr
The grid impedance is no longer within the permissible range ("Bfr"
or "Srr" is an internal message which has no meaning for the user).
The Windy Boy disconnects from the grid in order to avoid potential
damage or islanding. The impedance is calculated from the grid
impedance and the impedance of the Windy Boy's grid connection
cable (AC cable).
Check the grid impedance and the grid connection at the Windy
Boy. Use a cable with an adequate cross-section (= low
impedance), observe the advice to this effect in the installation
manual. If the grid impedance is still too high, ask the grid operator
if the grid characteristics at the feed-in point can be altered.
Error Code
Description
Summary of Contents for Windy Boy WB 1100LV
Page 2: ......
Page 6: ...Explanation of Symbols Used SMA Technologie AG Page 6 WB1100LV 11 FE2606 User Manual...
Page 10: ...Safety Instructions SMA Technologie AG Page 10 WB1100LV 11 FE2606 User Manual...
Page 28: ...Unit Description SMA Technologie AG Page 28 WB1100LV 11 FE2606 User Manual...
Page 30: ...Setting the Display Language SMA Technologie AG Page 30 WB1100LV 11 FE2606 User Manual...
Page 40: ...Turbine Operation SMA Technologie AG Page 40 WB1100LV 11 FE2606 User Manual...
Page 42: ...Maintenance and Care SMA Technologie AG Page 42 WB1100LV 11 FE2606 User Manual...
Page 50: ...Extensions SMA Technologie AG Page 50 WB1100LV 11 FE2606 User Manual...
Page 54: ...Technical Data SMA Technologie AG Page 54 WB1100LV 11 FE2606 User Manual...
Page 72: ...General Information SMA Technologie AG Page 72 WB1100LV 11 FE2606 User Manual...
Page 74: ...Stand Alone Systems SMA Technologie AG Page 74 WB1100LV 11 FE2606 User Manual...
Page 77: ......