Smappee EV Base
–
Installation manual - English
12
The maximum power rating for each connector is specified in the table below.
Power per connector
Connection
Input current
Output current
7.4 kW
1-phase
1 x 32 A
1 x 32 A
22 kW
3-phase
3 x 32 A
3 x 32 A
Prepare the mounting foundation
The Smappee EV Base is designed to be installed at ground level without the need for a separate
mount.
A stable and level ground needs to be prepared in advance. We advise a levelled concrete
foundation at ground level. It is also possible to have the foundation a little lower than ground level.
This allows the anchors to be masked and the EV Base to be integrated in the surrounding soil.
Depending on the subsoil, the size may vary. Please refer to the technical specifications of size and
weight to determine and construct a solid foundation for the EV Base.
Make sure the power supply cables and Ethernet cable are positioned through central position of
the floor plate recess.