Medi-Minder Installation Manual Rev1.11
9
6.2.4
PENDANTS Programming Options
User Key 1 (Pendant) Programming - (Ademco & British DTMF)
un-programmed
No Radio Key Pendant has been programmed for User Key 1
Help
Where
ON = Call
OFF = Call
PANIC = Call
Call
Where
ON = Emergency
OFF = Restore
PANIC = Emergency
Help/Call
Where
ON = Call
OFF = Restore
PANIC = Emergency
Call/Help
Where
ON = Emergency
OFF = Restore
PANIC = Call
Security
Where
ON = Arm
OFF = Disarm
PANIC = Call
Answer
Panic - Initiates Call or if rings are detected will answer the incoming phone call
Dementia
1 Button Blue Radio Key initiates Call on inactivity.
Door Bell
1 Button Key where Panic - Initiates Door Bell Tune 1, 2 and 3
Erase
Erase/Delete Programmed Radio Key.
To Program a NEW Radio Key Pendant (User Key):
1.
“
_u
” is displayed. Press the HELP Button.
2.
“
u1
” is displayed. Press the HELP Button again on the unit. The unit must display “- ” (unprogrammed).
Press any Button on a NEW Radio Key Pendant 3 times. The unit will beep with each Button press and
on the third Button press, beep twice to acknowledge the Radio Key Pendant is programmed. The status
display will also display and flash “
HP
” Help to indicate that the Radio Key Pendant is programmed.
NOTE: If the unit gives a long beep on Button presses and displays “- ” it indicates that the Radio Key
Pendant has already been programmed into the unit.
3.
Then, using the HELP Button to select an option
HP, CL, HC, CH, Sc, An, dE, b1, b2,
or
b3
for the
Radio Pendant. To
STORE
an option selected, press the CANCEL and HELP Buttons at the same time.
The unit will beep twice while flashing the display to acknowledge that the option has been selected.
4.
Press the CANCEL Button to move to the next Program Option.
To Erase a Radio Key Pendant (User Key):
1.
Go to the Pendant Option you wish to erase “
u1
” to “
u8
”.
2.
Press the HELP Button to select/until an option “
Er
” Erase.
3.
Press the CANCEL and HELP Buttons at the same time. The unit will beep twice while flashing the
display “- ” to indicate that a Radio Key Pendant has been erased.
4.
Press the CANCEL Button to move to the next Program Option.
User Key 1 (Pendant) Programming - (Contact ID Version only)
un-programmed
No Radio Key Pendant has been programmed for User Key 1
Security
Where
ON = Arm
OFF = Disarm
PANIC = 120
Medical
Where
ON = Arm
OFF = Disarm
Delay PANIC = 100
Duress
Where
ON = Arm
OFF = Disarm
Silent PANIC = 121
Delay Panic
Where
ON = Arm
OFF = Disarm
Delay PANIC = 100
Panic
Where
ON = Arm
OFF = Disarm
PANIC = 120
Answer
Initiates Delay Panic (120) or if rings are detected will answer the Phone Call.
Dementia
1 Button Blue Radio Key initiates Call on inactivity.
Door Bell
1 Button Key where Panic - Initiates Door Bell Tune 1, 2 and 3
Erase
Erase/Delete Programmed Radio Key.
to
User Keys (Pendants) 2 – 8 Programming
Default Values –
Deletes/Erases all Programmed User Keys (Pendants) u1 to u8
Warning! This will Deletes/Erases all Programmed User Keys (Pendants) u1 to u8
1.
“
dF
” is displayed. Press the CANCEL and HELP Buttons at the same time and the unit will beeps three
times to indicate that ALL Radio Key Pendants (User Keys u1 to u8) have been Deleted/Erased.
2.