Medi-Minder Installation Manual Rev1.11
10
6.2.5
DETECTORS Programming Options
Detector 1 Programming - (Ademco & British DTMF)
unprogrammed
No Detector has been programmed for Detector 1.
Fire
24 hour Alarm, always Active (initiates Emergency).
Alarm
In-active when DISARMED, Active when ARMED (initiates Emergency).
Inactivity
Alarms if un-active when DISARMED (initiates Emergency on Channel 7 only),
In-active when ARMED.
Door Bell
Sounds the programmed Door Bell Tune 1, 2 & 3 when in DISARMED Mode,
acts like a Alarm Detector when in ARMED Mode (initiates Emergency).
Erase
Erase/Delete Programmed Detector.
To Program a NEW Detector:
1.
“
_d
” is displayed. Press the HELP Button.
2.
“
d1
” is displayed. Press the HELP Button again on the unit. The unit must display “- ” (unprogrammed).
Trigger a NEW Detector (3 transmissions must be detected). The unit will beep with each transmission
and on the third transmission beep twice to acknowledge the Detector is programmed. The status display
will also display and flash “
Fi
” Fire to indicate that the Detector is programmed.
NOTE: If the unit gives a long beep on the first transmission and displays “- ” it indicates that the
Detectors has already been programmed into the unit.
3.
Then, using the HELP Button to select an option
Fi, Al, IA, b1, b2,
or
b3
for the Detector .
4.
To
STORE
an option selected, press the CANCEL and HELP Buttons at the same time. The unit will
beep twice while flashing the display to acknowledge that the option has been selected.
5.
Press the CANCEL Button to move to the next Program Option.
To Erase a Detector:
1.
Go to the Detector Option you wish to erase “
d1
” to “
d8
”.
2.
Then, using the HELP Button to select/until an option “
Er
” Erase.
3.
Press the CANCEL and HELP Buttons at the same time. The will beep twice while flashing the display “-
” to indicate that a Detector has been erased.
4.
Press the CANCEL Button to move to the next Program Option.
Detector 1 Programming - (Contact ID Version only)
unprogrammed
No Detector has been programmed for Detector 1.
Fire
24 hour Alarm, always Active (133).
Alarm
In-active when DISARMED, Active when ARMED (130).
Home
In-active when DISARMED, Active when ARMED & in HOME Mode (131).
Silent
In-active when DISARMED, Active when ARMED (Silent 130).
Inactivity
Alarms if un-active when DISARMED (initiates Emergency on Channel 7 only),
In-active when ARMED (355).
Door Bell
Sounds the programmed Door Bell 1, 2 & 3 tune when in DISARMED or in
HOME Mode, acts like an Alarm Detector when ARMED.
Erase
Erase/Delete Programmed Detector.
to
Detectors 2 – 8 Programming
Default Values –
Deletes/Erases all Programmed Detectors d1 to d8
Warning! This will Deletes/Erases all Programmed Detectors d1 to d8
1.
“
dF
” is displayed. Press the CANCEL and HELP Buttons at the same time and the unit will beeps three
times to indicate that ALL Detectors (Detectors d1 to d8) have been Deleted/Erased.
2.