Medi-Minder Installation Manual Rev1.11
16
6.2.9
SYSTEMS Programming Options
System Check (Check signal strength of Pendants and Detectors)
NO Pendants/Detectors Received or 1 to 9 Signal Strength
1.
“
_S
” is displayed. Press the HELP Button. “
SC
” is displayed. Press the HELP Button. Unit must display
“ -” to indicate that it is now ready to receive Test Signal Strength from Radio Keys and Detectors.
2.
To Test a Pendant or Detector, press any Button on a Radio Key Pendant or Trigger a Detector. The unit
will beep twice while flashing the display digit (
1, 2, 3, 4, 5, 6, 7, 8
or
9
). Press the CANCEL Button.
Unit CANCEL (GREEN) Light Brightness
0 = OFF, 1 = Dimmed or 2 = Bright
1.
“
Lb
” is displayed. Press the HELP Button to view programmed option. “
2
” is displayed.
2.
Pressing the HELP Button again to select (
0, 1
or
2
). To store an option selected, press the CANCEL and
HELP Buttons at the same time. The unit will beep twice while flashing the display to acknowledge that
the option has been selected. Press the CANCEL to move to the next Program Option.
Listen Pin
Enabled for listening to Monitoring Centre communication.
Alarms only on first attempt “n1” Primary No.
Disabled
1.
“
LP
” is displayed. Press the HELP Button to view programmed option. “
E
” is displayed.
2.
Pressing the HELP Button again to select between “
E
” or “
d
”. To store an option selected, press the
CANCEL and HELP Buttons at the same time. The unit will beep twice while flashing the display to
acknowledge that the option has been selected. Press the CANCEL Button to move to the next Option.
Microphone Sensitivity
0, 1, 2 or 3 Microphone Sensitive
1.
“
uP
” is displayed. Press the HELP Button to view programmed Microphone. “
1
” is displayed.
2.
Pressing the HELP Button again to select (
0, 1, 2
or
3
) Sensitivity. To store an option selected, press the
CANCEL and HELP Buttons at the same time. The unit will beep twice while flashing the display to
acknowledge that the option has been selected. Press the CANCEL Button to move to the next Option.
Speaker Volume
0, 1, 2 or 3 Speaker Volume
1.
“
SP
” is displayed. Press HELP Button to view programmed Speaker Volume.“
3
” is displayed.
2.
Pressing the HELP again to select (
0, 1, 2
or
3
) Volume. To store an option selected, press the CANCEL
and HELP Buttons at the same time. The unit will beep twice while flashing the display to acknowledge
that the option has been selected. Press the CANCEL Button to move to the next Program Option.
Line Balance Attenuation (Default 0 = 15.) refer SmartLink
Line In Level DTMF (Default 0 = Normal) refer SmartLink
Line Out Level DTMF (Default 0 = Normal) refer SmartLink
Report Pre-Time (Default 10 = Normal) refer SmartLink
Report Tone Time (Default 4 = Normal) refer SmartLink
Report Quiet Time (Default 4 = Normal) refer SmartLink
Report Between Time (Default 10 = Normal) refer SmartLink
Radio Repeater (Default d = Disabled) refer SmartLink
Default Values –
Sets all System Programming Options to Default Values
Warning! This will Sets all System Programming Options to Default Values
1.
“
dF
” is displayed. Press the CANCEL and HELP Buttons at the same time and the unit will beeps three
times to indicate that ALL System Programming Options have been defaulted.
2.
Press the CANCEL Button to move to the next Program Option.