Medi-Minder Installation Manual Rev1.11
26
13.2 CONTACT ID Reporting
This reporting is used to transmit alarms from a subscriber’s site to a Monitoring Centre via the telephone.
The transmission is done using DTMF tones. 14 digits are sent to report an alarm. The format is as follows:
SSSS 18 Q XYZ GG CCC E
SSSS
4 digit subscriber ID (Client Account Number).
18
Uniquely identifies this format as Contact ID.
Q
Event qualifier:
1 - New alarm
3 - Restore
XYZ
Event code, see table.
GG
Group code (always 00).
CCC
Zone or sensor number or user ID for Open/Close reports.
E
Error check.
Program Option
Event Code (XYZ)
Zone Number (CCC)
Detector Alarms
Detector Alarm Option - “Al”
130 Burglary
9 – 16
Detector Home Mode Option - “Ho”
131 Perimeter
9 – 16
Detector Fire Option - “Fi”
133 24 hour
9 - 16
Detector Silent Option - “Si”
130 Burglary
9 - 16
Tamper Alarms
Detector Tamper
383 Tamper
9 - 16
Panic Alarms
Medi-Minder unit Help Button
120 Panic Alarm
6
Hardwired Inputs 1 to 2 – “i1” to “i2”
120 Panic Alarm
21 - 22
Radio Keys Panic Option - “Pc” or “An”
120 Panic Alarm
1 - 8
Radio Keys Delay Panic Option – “dP”
100 Medical Alarm
1 - 8
Radio Keys Duress Option - “du”
121 Duress Alarm
1 - 8
Other Alarms
Supervision Option “Su”
355
9 - 16
Inactivity Detectors Option “IA”
130
15
Dementia Keys Option “dE”
130
1 - 8
Mains/AC Fail
301 AC Loss
0
Main unit Low Battery
302 Low System Battery
0
Detectors Low Battery
384 RF Transmitter Low Battery
9 - 16
Radio Keys (Pendants) Low Battery
384 RF Transmitter Low Battery
1 - 8
Open/Close Reports
401 O/C by user
1 - 8
Auto Exclude (Reed Switch only)
380 Sensor Bypass (Trouble)
9 – 16
Test Call
602 Period test report
0