A P P E N D I X B
Remotely managing your interactive flat panel
98
smarttech.com/kb/170446
N O T E
You must specify unique values for
set ubs1source
,
set usb2source
and
set usb3source
.
Video control
Use the following commands to identify video control settings.
Command
Response
Possible values
Standby
mode
get ambient
ambient=
[Value]
0–1023
No
get blacklevel
blacklevel=
[Value]
l
high
l
low
No
get brightness
brightness=
[Value]
0–100
No
get colortemp
colortemp=
[Value]
0–100
No
get contrast
contrast=
[Value]
0–100
No
get displaymode
displaymode=
[Value]
l
standard
l
ambient
l
vivid
l
ISF_Expert1
l
ISF_Expert2
No
get gamma
gamma=
[Value]
l
high
l
medium
l
low
l
1.9
l
2.2
l
2.4
No
get hsharpness
hsharpness=
[Value]
0–50
No
get hsize
hsize=
[Value]
[Dependent on the video
signal]
No
get phase
phase=
[Value]
[Dependent on the video
signal]
No
get saturation
saturation=
[Value]
0–100
No
get sharpness
sharpness=
[Value]
0–50
No
get tint
tint=
[Value]
0–100
No
get vsharpness
vsharpness=
[Value]
0–50
No
Use the following commands to assign video control settings.
Command
Possible values
Response
Standby
mode
set ambient
[Value]
=0–1023
ambient=
[Value]
No
set blacklevel
[Value]
l
=high
l
=low
blacklevel=
[Value]
No