DIODE MEASUREMENT

Test the voltage drop in diodes.

1.    Turn the Range Selector Switch to the Diode  

( ) position.

2.    Plug the red Test Lead into the V

Ω

mA (Center) 

Jack. Plug the black Test Lead into the Com 

(Bottom) Jack. Switch the Multimeter ON.

3.    Connect the red probe to the anode of the diode 

and the black to the cathode.

4.    The approximate forward voltage drop of the 

diode will be displayed in mV. If the connection 

is reversed only “1” will be shown.

BATTERY CHARGE MEASUREMENT

Test the amount of charge left in batteries.

!

!

WARNING 

This setting is for testing the charge of small 9V or 

1.5V batteries only. Never use this setting to test 

automotive or lead-acid batteries. The high current 

could cause damage to the meter and/or cause 

severe personal injury. Use the appropriate DC 

Voltage setting to test the open current voltage of 

such batteries instead.

1.    Turn the Range Selector Switch to the Battery  

( ) position.

2.    Plug the red Test Lead into the V

Ω

mA (Center) 

Jack. Plug the black Test Lead into the Com 

(Bottom) Jack. Switch the Multimeter ON.

3.    Connect the red probe to the positive terminal 

of the battery and the black to the negative 

terminal.

4.    The battery amperage under a load of 370 m

Ω

 

will be displayed to a resolution of .1mA.

5.    Normal amperage:  

For a standard 9V (6LR61) battery     = 25 mA 

For a 1.5 V “AA” (LR6) battery           = 4 mA

MAINTENANCE

1.    Wipe unit with a slightly damp cloth using 

a light detergent. Do not use solvents or 

abrasives.

2.    Remove battery if not in use for long periods.

3.    Store unit in a dry location.

4.    Other than the battery and fuse, there are no 

replacement parts on this unit. Repairs should 

be done by a qualified technician.

BATTERY/FUSE REPLACEMENT

To replace the battery or fuse:

1.    Remove the Test Leads from the multimeter.

2.    Turn the unit over.

3.    Remove both screws using a Philips 

screwdriver.

4.    Remove back cover.

5.    Pull battery/fuse out of unit and replace with the 

same. (9V battery or 500mA/250V fast-acting 

fuse)

6.    Replace cover and retighten screws.

© 2010 Distributed by  

Menard, Inc.

Eau Claire, WI 54703

GAR_TL_013_0410

Made in China

ADDITIONAL MULTIMETER PRECAUTIONS 

1.    Do not test voltage on AC circuits higher than 

750 volts.

2.    Do not test voltage on DC circuits higher than 

1000 volts.

3.    Do not test current on circuits higher than 10 

amps.

4.    Be careful not to apply voltage to the Test Leads 

when they are connected to the COM (Bottom) 

and V

Ω

mA (Center) Jacks and the Multimeter is 

in an Ohms testing setting. Damage can occur 

to the multimeter or the fuse may blow.

5.    Do no switch between testing modes with the 

multimeter connected to a circuit.

AC VOLTAGE MEASUREMENTS 

Measure AC conductors carrying up to 750 VAC, 

45-450 Hz.

1.    Turn the Range Selector Switch to 750 ACV 

setting. Always start with the highest range if 

the voltage is unknown.

2.    Plug the red lead into the V

Ω

mA (Center) Jack. 

Plug the black lead into the COM (Bottom) Jack. 

Switch the Multimeter ON.

3.    Carefully touch the exposed conductors with the 

tips of the probes to measure the voltage (not 

amperes).

4.    Read measurement. If the voltage is less than 

200 volts, set the Range Selector Switch to the 

lower range.

5.    When testing is complete, remove Test Leads 

and store with multimeter.

DC VOLTAGE MEASUREMENT

Measure DC conductors carrying up to 1000 VDC.

1.    Turn the Range Selector Switch to 1000 DCV 

setting.

2.    Follow the directions above under “AC Voltage 

Measurements”, only use the DC setting 

instead.

DC CURRENT MEASUREMENT

Measure DC conductors carrying up to 10 amperes.

1.    Turn the Range Selector Switch to the 10A 

position. Always start with the highest range if 

the amperage is unknown.

2.    Plug the red lead into the 10A (Top) Jack. Plug 

the black lead into the COM (Bottom) Jack. 

Switch the Multimeter ON.

3.    Carefully touch the exposed conductors with the 

tips of the probes to measure the amperage. 

NOTE:  Amperage is always tested in series with 

the circuit under test.

4.    Read measurement. If the reading is less than 

.2 AMPs, switch the red lead to the V

Ω

mA 

(Center) Jack and set the Range Selector Switch 

to the 200mA setting.

5.    When testing is complete, remove Test Leads 

and store with multimeter.

RESISTANCE MEASUREMENTS

Measure circuit resistance up to 2000K Ohms.

!

!

WARNING 

NEVER measure resistance on a circuit with voltage 

running through it.

1.    Turn the Range Selector Switch to the 200 

Ω

 

position.

2.    Plug the red Test Lead into the V

Ω

mA (Center) 

Jack. Plug the black Test Lead into the Com 

(Bottom) Jack. Switch the Multimeter ON. Short 

the Test Leads together. The meter should read 

“0” Ohms.

3.    Touch the exposed conductors with the tips of 

the Test Leads.

4.    Read measurement. If the reading is “1”, set the 

Range Selector Switch to the next higher Ohm 

(

Ω

) position.

TRANSISTOR (HFE) MEASUREMENTS

Test transistors to ensure proper function.

1.    Turn the Range Selector Switch to the hFE 

position. Switch the Multimeter ON.

2.    Insert the transistor pins into the appropriate 

hFE jack (NPN or PNP) according to the EBC 

(Emitter, Base, Collector) sequence.

3.    The meter will show the approximate hFE value.

GAR_TL_013_0410_Smart_Electrician_Ins_Manual_364-5017_Digital_Multimeter.indd   2