HALOGEN LAMP INSTALLATION

WARNING

RISK OF SEVERE BURNS. LAMP HEAD AND BULB 

ARE EXTREMELY HOT DURING AND IMMEDIATELY AFTER USE.

 

Touching lamp heads or bulbs with bare hands while work light is on 

can cause severe burns. Turn off and unplug work light and allow it to 

cool completely before attempting to change bulbs.

CAUTION

: RISK OF DAMAGING BULB! NEVER TOUCH BULB 

SURFACE WITH YOUR BARE HANDS!

The natural oil from your skin can leave a residue that could cause the 

bulb to fail prematurely. If you accidentally touch the bulb with your 

bare hands, wipe the bulb thoroughly with alcohol and soft cloth

or tissue before installing. ALWAYS USE A CLEAN CLOTH OR TISSUE 

WHEN HANDLING THE BULB.

WARNING

: RISK OF FIRE AND PERSONAL INJURY.

The lamp head on this work light is designed to operate safely with 
two 

300

-watt bulb. To avoid damage to the work light, DO NOT USE A 

BULB OVER 

300

-watts IN THIS WORK LIGHT.

Install halogen bulb into lamp head

The halogen bulb (F) is shipped in a protective box inside the lamp 

head.

1)

 Remove the center screw at the top of the lamp head (A) and lower 

the hinged frame with glass lens. 

Fig. 5

 and 

Fig 6.

2)

 Remove bulb (F) from its box and wrapper, being careful not to 

touch the bulb with your bare hands. Only use a clean cloth or tissue 

to handle the bulb

3)

4)

 Insert the other ceramic end of the bulb into the other lamp holder 

socket. Make sure that the bulb (F) makes secure contact at both lamp 

holder sockets. When properly installed, the bulb can be rotated about 

45° (1/8 of a turn) on its axis with very little or no resistance.  Replace 

the hinged front frame with glass lens. Then replace and tighten the 

center screw.  Repeat above steps for other lampholder.

HALOGEN LAMP REPLACEMENT

WARNING

Risk of severe burns. Bulb housing and bulbs are 

extremely hot during and immediately following use. Touching 

housing or bulb with bare hands while unit is lit can cause se-

vere burns. Unplug light and allow it to cool completely before 

attempting to change lamp.

To remove lamp:

1. Unplug and allow the light housing (A) and bulb (F) to cool.

2. Remove the center screw at the top of the light head (A) and lower 

the hinged lens cover.

3. Using a cloth to safely grasp the burned out lamp (F), gently push 

the lamp to the right. You will feel the lamp holder spring retract, free-

ing the other end of the lamp.

4. Lift and remove the bulb (F).

To replace lamp:

To install a new lamp, follow all instructions in the HALOGEN LAMP IN-

STALLATION section of this manual.

SAVE THESE INSTRUCTIONS! 

SAVE THESE INSTRUCTIONS! 

Fig. 5

Fig. 6

Fig. 7

 Hold the bulb (F) at its center with a clean cloth or tissue and 

gently push one ceramic end of the bulb (F) into the bulb holder

to engage right side first. See 

Fig.7

Summary of Contents for 3705414

Page 1: ...hin three 3 years from the date of purchase return it along with the proof of date of purchase to place of purchase and it will be replaced with the same or comparable model free of charge This warranty gives you specific legal rights and you may have other rights that vary from state to state This warranty is void if damage or defect has resulted from accident abuse misuse or faulty repair IN NO E...

Page 2: ...O EXCESSIVE ULTRAVIOLET RADIATION 1 Use only 3 wire UL listed outdoor extension cords that have 3 prong grounded plugs and grounded receptacles that accept the work light s plug 2 Use only with a 16 gauge AWG extension cord of cord type SW A SOW SOW A STW STW A STOW STOW A SJW SJW A SJOW SJOW A SJTW A or SJTOW SJTOW A 3 To avoid electrical shock do not use near water or in areas where water may ac...

Page 3: ...remain in light if skin feels warm 8 Do not look directly at the lighted lamps to avoid eye injuries 9 Always keep the work light away from any flammable surfaces or materials 10 Use only with 300 Watt bulb or lower wattage bulb in socket at top of lamp head Use only with 300 Watt bulb or lower wattage bulb in socket at bottom of lamp head See Fig 2 11 Never touch the halogen lamp surface with your...

Page 4: ...clean cloth or tissue to handle the bulb 3 4 Insert the other ceramic end of the bulb into the other lamp holder socket Make sure that the bulb F makes secure contact at both lamp holder sockets When properly installed the bulb can be rotated about 45 1 8 of a turn on its axis with very little or no resistance Replace the hinged front frame with glass lens Then replace and tighten the center screw...

Page 5: ...d Using the handle adjust the lamp head to desired position and retighten knob See Fig 8 WARNING RISK OF PERSONAL INJURY To avoid being burned always hold the work light by its grip handle when making adjustments Power Switch The lamp head has Two 2 ON OFF style switches See Fig 9 Always turn the lamp head OFF before unplugging the worklight WARNING RISK OF FIRE DO NOT aim the work light at flammab...

Page 6: ...ere may be a poor connection between lamp holder and bulb Bulb needs replacement Try re installing the bulb Refer to Halogen Bulb Installation section of this manual Remove bulb and check for a break in the filament wire Replace bulb if necessary Refer to Halogen Bulb Installation section of this manual The work light comes on but the lights are dimmed Improper voltage or power supply The work ligh...

Reviews: