INTRODUCTION

 

 

 

INTRODUCTION

LCD Display Signal

SYMBOL

DESCRIPTION

Systolic blood pressure

High pressure result

Diastolic blood pressure

Low pressure result

EXPLANATION

Current Time 

Time(year:month:day:hour:minute)

mmHg

Measurement Unit of the blood pressure

Battery Indicator

Indicate the current battery level 

Irregular heartbeat

Irregular heartbeat

Heartbeat

Heartbeat detection during measurement

Shaking reminder

Shacking will result in inaccurate

MAINTENANCE AND STORAGE CAUTIONS

*  This device contains sensitive components and must be treated with caution. Observe the 

storage and operating conditions described in this booklet.

*  When not in use, store the device in a dry room and protect it against extreme moisture, 

heat, lint, dust, and direct sunlight. Never place any heavy objects on the storage case.

*  Keep the unit out of reach of infants, young children, or pets to avoid inhalation or 

swallowing of small parts and possible strangulation from the hose or cable.

*  Cleaning: Dusty environments may affect the performance of the unit. Please use a soft 

cloth to clean the whole unit before and after use. Don’t use abrasive or volatile cleaners.

*  Do not wash the cuff in a washing machine or dishwasher.

*  The service life of the cuff may vary by the frequency of washing, skin condition, and 

storage state. The typical service life is 10,000 uses.

*  Before use, make sure the device functions safely and is in proper working condition. 

Check the device and do not use the device if it is damaged in any way. The continuous 

use of a damaged unit may cause injury, improper results, or danger.

*  It is recommended that the performance of the device be checked every 2 years.

*  Please use only accessories and detachable parts specified/authorized by Smart Meter.

*  Please dispose of the device and accessories according to local guidelines.

*  Do not open or attempt to repair or service the device at any time.

*  If you have any questions or problems with this device, please contact Smart Meter 

Customer Service.

 Signal indication

Indicates the signal situation in the communication 

process.

CAUTION

Blink to indicate that the data is being sent, the 

send success will disappear.

Data transmission indication

Summary of Contents for iBloodPressure SMBP802-GS-001

Page 1: ...Model SMBP802 GS 001 User Manual To use the monitor correctly and safely please read the manual thoroughly Please keep this manual in order to reference in future Manufactured for Smart Meter LLC 201...

Page 2: ...a Measurement INFORMATION FOR USER 14 Tips for measurement Maintenances ABOUT BLOOD PRESSURE 16 What are systolic pressure and diastolic pressure What is the standard blood pressure classification Ir...

Page 3: ...revent any damage to the device SN Symbol for MANUFACTURE DATE General Description The iBloodPressure monitor features blood pressure measurement pulse rate measurement and cellular result transmissio...

Page 4: ...presence of a flammable anesthetic mixture with air of oxygen or nitrous oxide This unit is not suitable for continuous monitoring during medical emergencies or operations INTRODUCTION INTRODUCTION T...

Page 5: ...onments may affect the performance of the unit Please use a soft cloth to clean the whole unit before and after use Don t use abrasive or volatile cleaners Do not wash the cuff in a washing machine or...

Page 6: ...ims The display does not light up Do not use new and used batteries together Do not use different types of batteries together Do not dispose the batteries in fire Batteries may explode or leak Remove...

Page 7: ...so that the tube exits towards the hand Place your arm through the cuff loop with your palm facing up Position the cuff s edge about an inch 2 3 cm above the elbow Align the marker located to the rig...

Page 8: ...links on the LCD indicates data is transmitting Taking a Measurement Transmitting results Tip You can press START STOP button at any time to stop measuring during the process 3 If the data is successf...

Page 9: ...y place and avoid the sunshine Avoid intense shaking and dropping Use a damp cloth to remove dirt Avoid contact with water clean exterior with a dry cloth Avoid dusty places and unstable temperatures...

Page 10: ...t the day due to weather emotion exercise etc Also there is the white coat effect which means blood pressure usually increases in clinical settings It is okay to measure on either arm however there ma...

Page 11: ...is allowed Power supply Display mode Measurement mode Oscillographic testing mode Measurement range Measurement perimeter of the upper arm Weight External dimensions Attachment Mode of operation Cont...

Page 12: ...device labels labelling and information to be supplied Part 1 General requirements IEC 80601 2 30 2018 Medical electrical equipment Part 2 30 Particular requirements for the basic safety and essential...

Page 13: ...d amateur radio bands between 0 15 MHz and 80 MHz 6V For AC power port 3 Vrms 6 Vrms in ISM and amateur radio bands 80 AM at 1 KHz 10 V m 80 MHz 2 7 GHz 80 AM at 1 kHz 10 V m 80 MHz 2 7 GHz 80 AM at 1...

Page 14: ...Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if...

Reviews: