What are systolic pressure and diastolic pressure? 

press

artery

vein

blood discharging

Systolic

relax

blood entering

Diastolic  

When ventricles contract and pump blood out 
of the heart, the blood pressure reaches its 
maximum value in the cycle, which is called 
systolic pressure. When the ventricles relax, 
the blood pressure reaches its minimum value 
in the cycle, which is called diastolic pressure.

Irregular Heartbeat Detector

ABOUT BLOOD PRESSURE

An irregular heartbeat is detected when a heartbeat rhythm varies while the device is 
measuring systolic pressure and diastolic pressure. During each measurement, the 
blood pressure monitor will keep a record of all the pulse intervals and calculate their 
average value. If there are two or more pulse intervals with an average difference
between each interval of more than ±25%, or if there are four or more pulse intervals,
with an average difference between each interval of ±15%, then the irregular
heartbeat symbol will appear on the display with the measurement result.

ABOUT BLOOD PRESSURE

Why does my blood 
pressure fluctuate 
throughout the day?

Is the result the same if measuring on the 
right arm?

Why do I get a different blood pressure at 
home compared to the hospital?

1. Individual blood pressure varies throughout the day. It is also affected by the 

way you tie your cuff and your measurement position. It is recommended that 
you take your measurement under the same conditions.

2.  If you take medicine, your pressure may vary more.

3.  Wait at least 3 minutes between measurements.

The blood pressure is different throughout the day due to weather, 
emotion, exercise, etc. Also, there is the “white coat” effect, which means 
blood pressure usually increases in clinical settings.

It is okay to measure on either arm, however; there may be different results 
for some people. We suggest you measure the same arm every time. 

If the cuff is tied properly. 
If the cuff is too tight or too loose.
If the cuff is tied on the upper arm.
If you feel anxious.
Take 2-3 deep breaths before you begin measuring. 
Relax for 4-5 minutes until you are calm.

What is the standard blood pressure classification?

The chart on the right is the 
standard blood pressure classifi-
cation published by American

Heart Association (AHA).

Please consult a physician if your result falls outside the range. Please note
that only a physician can tell whether your blood pressure value has 
reached a dangerous point.  

Blood Pressure Category

Normal

Prehypertension

High Blood Pressure

(Hypertension) Stage 1

High Blood Pressure

(Hypertension) Stage 2

Hypertensive Crisis

(Consult your doctor immediately)

Systolic

mmHg (upper#)

Diastolic

mmHg (lower#)

less than 120

120-129

130-139

140 or higher

Higher than 180

and

or

or

and/or

less than 80

80-89

90 or higher

Higher than 120

This chart reflects blood pressure categories defined by American Heart Association.

and

less than 80

Pay special attention to the following when you 
measure your blood pressure at home:

The appearance of the IHB icon indicates that a pulse irregularity consistent with an 
irregular heartbeat was detected during measurement. Typically this is NOT a cause 
for concern. However, if the symbol appears often, we recommend you seek medical 
advice. Please note that the device does not replace a cardiac examination, but serves 
to detect pulse irregularities at an early stage. 

CAUTION

CAUTION

Summary of Contents for iBloodPressure SMBP802-GS-003

Page 1: ...04 User Manual To use the monitor correctly and safely please read the manual thoroughly Please keep this manual in order to reference in future Manufactured for Smart Meter LLC 5501 W WATERS AVE STE...

Page 2: ...a Measurement INFORMATION FOR USER 14 Tips for measurement Maintenances ABOUT BLOOD PRESSURE 16 What are systolic pressure and diastolic pressure What is the standard blood pressure classification Irr...

Page 3: ...rate with arm circumference ranging from 22cm to 45cm about 8 17 The device can be used to detect irregular heartbeat It is intended for adult indoor use only Contraindications Warranty Smart Meter L...

Page 4: ...al emergencies or operations INTRODUCTION INTRODUCTION To avoid measurement errors avoid electromagnetic field radiated interference signals or electrical fast transient burst signals Wireless communi...

Page 5: ...vironments may affect the performance of the unit Please use a soft cloth to clean the whole unit before and after use Don t use abrasive or volatile cleaners Do not wash the cuff in a washing machine...

Page 6: ...lay dims The display does not light up Do not use new and used batteries together Do not use different types of batteries together Do not dispose of the batteries in fire Batteries may explode or leak...

Page 7: ...so that the tube exits towards the hand Place your arm through the cuff loop with your palm facing up Position the cuff s edge about an inch 2 3 cm above the elbow Align the marker located to the rig...

Page 8: ...on the LCD indicates data is transmitting Taking a Measurement Transmitting results Tip You can press START STOP button at any time to stop measuring during the process 3 If the data is successfully t...

Page 9: ...y place and avoid the sunshine Avoid intense shaking and dropping Use a damp cloth to remove dirt Avoid contact with water clean exterior with a dry cloth Avoid dusty places and unstable temperatures...

Page 10: ...t the day due to weather emotion exercise etc Also there is the white coat effect which means blood pressure usually increases in clinical settings It is okay to measure on either arm however there ma...

Page 11: ...fasten the cuff and then measure again The measurement process does not detect the pulse signal Loosen the clothing on the arm and then measure again Not able to calculate measurement failed Relax for...

Page 12: ...RMANCE with regard to electromagnetic disturbances for the excepted service life 2 Guidance and manufacturer s declaration electromagnetic emissions and immunity Table 1 Guidance and manufacturer s de...

Page 13: ...ds between 0 15 MHz and 80 MHz 6V For AC power port 3 Vrms 6 Vrms in ISM and amateur radio bands 80 AM at 1 KHz 10 V m 80 MHz 2 7 GHz 80 AM at 1 kHz 10 V m 80 MHz 2 7 GHz 80 AM at 1 kHz Radiated RF IE...

Page 14: ...interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following mea...

Reviews: