-8-
Electrical Connection
Motor Connection
Your Smart Roller Shutter Opener is equipped with a
wiring harness with identical plugs at both ends. To
connect the motor to the control box simply connect each
end of the cable to the respective sockets on the drive
motor and control box. Also ensure that the battery back
up module is connected to the terminal under the main
control box (Fig. 6).
Note:
If the control box included with your opener is fitted
with an open, “dead-man” close and emergency
stop switches and isolation lock as depicted in Fig.
6, these switches are prewired in the factory ready
to use.
Menu Quick Reference Guide
Use the table below as a reference to guide you through
the menu system and parameters.
Fig. 6
Motor Connector Cable
Open Switch
Dead-man Close Switch
Emergency Stop Switch
Power Cable
Isolation Lock
Battery
Back Up
Menu Item
Factory Default
Options
1
Pedestrian Mode
On
On/Off
2
Lock
Pulse
Pulse/Hold (Magnetic)
3
Obstruction Setting 03
00 – 09
4
Open Speed
80%
50%-100% (by 5%)
5
Close Speed
80%
50%-100% (by 5%)
6
Motor Delay
On (only for DualMotor)
On/Off
7
Photo Beam
Off
On/Off
7.1
PE Close
Off (only for Photo Beam Mode)
On/Off
7.2
Sequence Mode
Off (only for Photo Beam Mode)
On/Off
8
Auto Close
Off (only for Photo Beam Mode)
On/Off
8.1
Time Delay
30 secs
5-400 secs
8.2
PED Close
Off
On/Off
8.3
PED Time Delay
30 secs
5-400 secs
9
Transmitter Button PB=1 PD=2
PB, PD, OP, CL
10
Hands Free Learn
On
On/Off
© June 2009 Smart Openers Pty Ltd