-16-
Setting Auto-Close Mode
Auto-Close Mode allows the gate to close automatically
once the PE safety beam has been tripped and the
preset time has elapsed. This function is only available
with the addition of a functioning photo-electric safety
beam (Factory Default = Off).
Auto-Close Mode
allows you to set a timer from
001–180 seconds before the gate begins to close. In
this mode the gate will close if the photo beam is not
triggered after the time has elapsed.
Important:
If the photo beam is tripped within the time
limit the gate will close 5 secs after the beam is restored.
PE Close Mode
allows the gate to close 5 secs after the
photo beam has been tripped.
Important:
The gate will remain open until the beam is
tripped.
1.
Make sure that a functioning PE beam is connected
and Photo Beam Mode is set to On as per Page 11.
2.
Press
MENU
for 3 secs then
SET
to cycle though to
Auto-Close
or
PE Close
.
3.
Press
MENU
to choose
On
.
4.
Press
SET
to confirm or
MODE
to save and exit.
Setting Auto-Close Timer
Delay
Auto-Close Time delay is used with Auto-Close Mode to
allow the gate to close automatically after the timer has
elapsed.
Note:
Auto-Close Mode must be enabled to use this
function.
1.
Press
MENU
for 3 secs then
SET
to cycle though to
Auto-Close
Delay
.
2.
Press and hold
MENU
to increase or
PB
to decrease
delay time in 5 sec increments (Max. 400 secs).
3.
Press
SET
to confirm or
MODE
to save and exit.
Setting Pedestrian Auto-
Close and Timer Delay
If Pedestrian Mode is activated the above functions are also
available for Pedestrian Mode. Follow the above procedure
to enable auto-close and set a time delay as required.
Hands Free Learning
Hands Free Learning allows the coding of new transmitters
via an existing already coded remote instead of pressing
the LEARN button. This function is useful if multiple
remotes are to be coded for one site.
(Factory Default = On).
1
To disable this function press
MENU
for 3 secs then
SET
to cycle though to
HF Learning On
.
2
Press
MENU
to choose
Off
(Fig. 34).
3
Press
SET
to confirm or
MODE
to save and exit.
© November 2011 Smart Openers Pty Ltd
Auto Close
On
Auto Close
060 secs
PE Close
On
Auto Close
030 secs
Fig. 30
Fig. 32
Fig. 31
Fig. 33
HF Learn
On
Fig. 34