Main power breaker
Figure 12
WARNING:
Never operate the system without the filler/breather plug installed. Contaminants
may enter the hydraulic fluid through the filler opening, causing premature wear on
the hydraulic components and void the system’s warranty.
Never apply a load to the generator while there is air trapped in the hydraulic fluid.
Damage to the system’s hydraulic components, as well as ruptured hoses, may
result and void the system’s warranty.
Always run the purge cycle after installation, after replacing the hydraulic fluid and
the filter, or after making any other repairs that may allow air into the hydraulic
system. Failure to do so will void the system’s warranty.
Enabling System Purge Option
The purge option can also be set by performing the following steps:
Step 3: Hold Mode
until Amps Line 1
Blinks
. Release
switch so
appears.
Step 4: Press mode to
make
appear.
Step 5: Press On/Off
until