57 |
MAINTENANCE AND TROUBLESHOOTING
There is a small red
×
on the SMART Board
icon .
(continued)
The USB CCID Smart
Card driver installed on
your computer failed
to access the Atmel®
chip on your interactive
whiteboard’s USB hub.
NOTE
The USB CCID
Smart Card driver
encrypts data from
each of your
interactive
whiteboard’s
cameras, which
connect to the
USB hub.
Check the SMART Board service
log to see if there is an error
indicating that the USB CCID
Smart Card driver failed to access
the Atmel chip. If there is an error,
disconnect and reconnect the
USB cable.
To check the SMART Board
service log:
1. In the Windows notification
area, select the
SMART Board
icon , and then select
Control Panel
.
The SMART Notebook control
panel opens.
2. Select
About Software and
Product Support
>
Tools
>
Diagnostics
.
The
SMART Board
Diagnostics
window opens.
3. Check the SMART Board
service log file. If you see the
following error, the USB CCID
Smart Card driver failed to
access the Atmel chip:
22: (4/22 10:13:23.114)
- Error: The data
necessary to complete
this operation is not
yet available.
(0x8000000a). SBV280
init failed due to
Smart Card not
connected. Unplug and
replug of usb cable
might fix the error.
4. Close the
SMART Board
Diagnostics
window, and then
close the SMART Notebook
control panel.
Symptoms
Cause
Solution
Summary of Contents for SMART Board V280
Page 10: ...viii CONTENTS...
Page 18: ...8 INTRODUCING YOUR SMART BOARD V280 INTERACTIVE WHITEBOARD...
Page 30: ...20 INSTALLING AND SECURING YOUR SMART BOARD V280 INTERACTIVE WHITEBOARD...
Page 52: ...42 GETTING STARTED WITH SMART NOTEBOOK SOFTWARE...
Page 72: ...62 MAINTENANCE AND TROUBLESHOOTING...
Page 86: ...76 HARDWARE ENVIRONMENTAL COMPLIANCE...
Page 92: ......
Page 93: ......
Page 94: ...Toll Free 1 866 518 6791 U S Canada or 1 403 228 5940 www smarttech com...