Hardware Preparation and Installation
ATCA-F125 (6873M Artwork) Installation and Use (6806800J94N)
35
Table 2-1
Environmental Requirements
Requirement Operating
Non-Operating
Temperature
Normal Operation: +5°C (41°F) to
+40°C (104°F) according to Telcordia
GR-63-CORE (NEBS) and ETSI EN
300 019-1-3, Class 3.1
Exceptional Operation: -5°C (23°F) to
+55°C (131°F) according to Telcordia
GR-63-CORE (NEBS)
Note: this exceeds ETSI EN 300 019-
1-3, Class 3.1E requirements (-5°C to
+45°C)
-40°C (-40°F) to +70°C (158°F) according
Telcordia GR-63-CORE (NEBS) and
ETSI EN 300 019-1-2, Class 2.3
Note: This exceeds ETSI EN 300 019-1-
1, Class 1.2 requirements (storage from -
25°C to +55°C
Note: This may be further limited by
installed accessories
Temp. Change
±0.25°C/min according to Telcordia
GR-63-CORE
±0.2°C/min
Relative
Humidity
Normal Operation: 5%rH to 85%rh
non-condensing
Exceptional Operation: 5%rH to
90%rh non-condensing
According to Telcordia GR-63-CORE
(NEBS) and EN 300 019-1-3, Classes
3.1 and 3.1E
5%rH to 95%rH non-condensing
According to Telcordia GR-63-CORE
(NEBS) and EN 300 019-1-1, Classes 1.2
and 2.3
Vibration
1g from 5 to 200Hz and back to 5Hz at
a rate of 0.25 octave/minute
(according to Telcordia GR-63-core)
5-20Hz at 0.01 g
2
/Hz (according to
Telcordia GR-63-core and ETSI EN 300
019-2-2)
20-200Hz at -3 dB/octave Hz (according
to Telcordia GR-63-core and ETSI EN
300 019-2-2)
Random 5-20Hz at 1m
2
/s
3
Random 20-200Hz at 3m
2
/s
3
Shock
Half-sine, 11 ms at 30m/s
2
Blade level packaging
Half-sine, 6ms at 180m/s
2
Free Fall
-
1.2m/packaged (according to ETSI 300
019-2-2)
100 mm unpackaged (according to
Telcordia GR-63-core)