APPENDIX B
REMOTELY MANAGING YOUR INTERACTIVE FLAT PANEL
108
smarttech.com/kb/170446
Command
Possible values
Response
Standby
mode
set opsfail
[Value]
l
=on
l
=off
opsfail=
[Value]
No
set proximity
[Value]
l
=on
l
=off
proximity=
[Value]
No
set proximitydetected
[Value]
l
=yes
l
=no
proximitydetected=
[Value]
No
set proximityreenable
[Value]
=1–10
proximityreenable=
[Value]
No
set readystatebrightness
[Value]
=0–100
readystatebrightness=
[Value]
No
set testmode
[Value]
l
=on
l
=off
testmode=
[Value]
No
set upgradeicp
[Value]
l
=on
l
=off
upgradeicp=
[Value]
No
set upgrademain
[Value]
l
=on
l
=off
upgrademain=
[Value]
No
set videomute
[Value]
l
=on
l
=off
videomute=
[Value]
No
set vposition
[Value]
l
+
[Incremental value]
l
-
[Incremental value]
l
=
[Range of values dependent
on the video signal]
vposition=
[Value]
No
set welcome
[Value]
l
=on
l
=off
welcome=
[Value]
No
set welcometimeout
[Value]
l
+
[Incremental value]
l
-
[Incremental value]
l
=5–30
welcometimeout=
[Value]
No
Service information
Use the following commands to identify service information settings.
Command
Response
Possible values
Standby
mode
get failurelog
failurelog=
[Value]
l
normal
l
power
l
displayfan
l
opsfan
l
inverter
l
temperature
No
get statereporting
statereporting=
[Value]
l
on
l
off
No
get totalhours
totalhours=
[Value]
0–40000
No