CHAPTER 2
MOUNTING YOUR INTERACTIVE FLAT PANEL
15
smarttech.com/kb/170446
l
Use M8 screws to fasten the wall bracket.
The following table presents the recommended screw length and fasten force for the
different models:
Models
Screw length
1
Fasten force
8070i-G4-SMP 23 mm + x mm < M8 < 29 mm + x mm
97.36–123.91 in-lb.
(11–14 N m)
8084i-G4-SMP 23 mm + x mm < M8 < 29 mm + x mm
Max. 10.6 in-lb.
(1.2 N m)
CAUTION
Do not over-tighten the
screws.
NOTE
SMART recommends M8 × 30 mm mounting screws for standard installations where the
total wall mount bracket and washer thickness is less than 7 mm.
l
Because the receptacles might not be easily accessible after the installers mount the
interactive flat panel, consider connecting cables for power, computers and other devices
while the interactive flat panel is still in its packaging or is suspended from a lifting device (see
l
Before turning on the interactive flat panel for the first time, clean the DViT camera windows
and reflective tape following the instructions in
Cleaning the DViT camera windows and
Choosing a location
Do the following when choosing a location for the interactive flat panel:
l
Do not install the interactive flat panel in a location where a door or gate could hit it.
l
Do not install the interactive flat panel in an area where it will be subjected to strong vibrations
or dust.
l
Do not install the interactive flat panel near where the mains power supply enters the building.
l
Ensure adequate ventilation or provide air conditioning around the interactive flat panel so
that heat can flow away from the unit and the mounting equipment.
1
Where x is the total thickness of the wall bracket and washer.