background image

© 2020 Compacta International, Ltd.—Rev  0.1 05/28/2020

 

IoTeMtr and Smartenit are trademarks of Compacta International, Ltd

 

Zigbee is a registered trademark of the zigbee alliance

 

Quick Start Guide

 

Technical Support      

support@smartenit.com

 

Setup (Cont.)

 

1)

 

Factory Reset (Restore Factory Settings)

 

 

While powering the device, press the SET button and release it once the device powers up.  Alternatively, if 

the device is already joined to a Zigbee network, quickly tap the SET button 13 times.  The Status LED will go 

out for 1 second and then begin flashing rapidly.  The IoTeMtr will then search for an open Zigbee network 

to join.

 

2)

 

Joining device to a Zigbee network

 

1.

 

Set network controller to discover devices (Open Permit Join)

 

2.

 

As the IoTeMtr joins, the Status LED blinking rate will slow until it stays solid, indicating it has fully joined 

the Zigbee network.

 

3)

 

Binding to be controlled by other devices

 

To allow On/Off control by another device, tap the SET button once quickly and within 1/2 second press 

and hold it for 3 seconds.  The Status LED will blink per the pattern described in the Status LED Indications 

table above.

 

4)

 

Allowing other devices to join Zigbee network (Open Permit Join)

 

As a Zigbee 

Router

”, 

the IoTeMtr can also be put in discovery mode to permit other devices to join the 

Zigbee network.  Do note that ultimately the network manager device will decide whether to allow the new 

device to fully join.  Assuming the IoTeMtr is already in a Zigbee network, it can open the network for other 

devices to join as follows:

 

1.

 

Press and hold the SET button for 6 seconds.  The STATUS LED will blink once per second and the net-

work will be open for joining for up to 4 minutes

 

2.

 

Permit

-

join can be stopped by pressing and holding the SET button for 3 seconds.  The LED will stop 

blinking.

 

Summary of Contents for IoTeMtr 3017

Page 1: ...e device requires voltage and current inputs plus the supply voltage to power the unit itself This guide shows how to connect the input voltage and current measurement transformers CTs Install with the tips and suggestions below to get the benefits of the Internet of Things through your automation controller Electrical Installation For indoor installation only as supplied When installing outdoors ...

Page 2: ...International Ltd Rev 0 1 05 28 2020 IoTeMtr and Smartenit are trademarks of Compacta International Ltd Zigbee is a registered trademark of the zigbee alliance Quick Start Guide Technical Support support smartenit com ...

Page 3: ... to the selected channel LED will then blink the number of tapped times to confirm selection SET Pushbutton Functionality Operation Pushbutton Device Behavior Leave Network Tap 13 times Status LED will begin fast blinking Close Permit Join Press and hold for 3 seconds when de vice is in open per mit join Status LED will stop flashing Soft Reset Reboot Device Tap 10 times Request Firmware Update OT...

Page 4: ...ys solid indicating it has fully joined the Zigbee network 3 Binding to be controlled by other devices To allow On Off control by another device tap the SET button once quickly and within 1 2 second press and hold it for 3 seconds The Status LED will blink per the pattern described in the Status LED Indications table above 4 Allowing other devices to join Zigbee network Open Permit Join As a Zigbe...

Reviews: