Operating Manual
OM_Axessor_CIT_V024_20170518_EN.pdf
Subject to change without prior notice
Page 107
Axessor CIT
9.2
Electronics
General
Power supply
3 Alkaline or Lithium batteries 1.5 V LR6 (AA, AM3,
E91), service life approx. 1-2 years (with 1 opening/
closing cycle per working day, no load on lock bolt)
Memory
Non-volatile (protected against power failure)
Display
Iconographic LCD with high contrast, display lan-
guage user selectable (English, Dutch, French, Ger-
man, Hungarian, Italian, Polish, Portuguese, Spanish
and Turkish).
Keypad
Silicone keys
(10 numeric, 4 function, 2 navigation keys).
Interfaces
Outputs
2 potential free contacts for alarms (30VDC / 2A,
50VAC / 0.5A with resistive load).
Output 1: Duress Alarm (factory setting)
Output 2: Bolt or motor open (factory setting)
With the Programming Software AS284-USBW or
AS284-NETW the outputs can be programmed for
different applications. For this, e.g. the following
events are available:
• Lock open
• Door open
• Active time delay
• Active penalty time
• Duress code entry
• Battery compartment open
• and more...
Inputs
Input 1 (signal-triggered 12VDC / 20mA):
not programmed (factory setting)
Input 2 (contact triggered):
not programmed (factory setting)
With the Programming Software AS284-USBW or
AS284-NETW the inputs can be programmed for
different functions, e.g.:
• Remote activation - remote disabling
• Door contact, interruption of delay time - override
non return time delay
• etc.
Note: not all events can be assigned to the inputs.
USB
Connection to a computer for configuration with
AS284-USBW or AS284-NETW Programming
Software
Axessor CIT bus
To connect external power supply or eBox
Summary of Contents for Axessor CIT