Operating Manual
OM_Axessor_CIT_V024_20170518_EN.pdf
Subject to change without prior notice
Page 27
Axessor CIT
4.5
Perform wiring check after lock installation
Requirement
To perform wiring check the door must be open.
1. Carefully slide out the battery compartment until it comes to a stop.
2. Insert the 3 enclosed batteries (3x AA mignon, Alkaline type) according
to the markings in receptacles –
observe polarity!
As soon as the batteries are inserted a test routine is initiated. The fol-
lowing displays appear successively (version display may vary) and the
„BEEP signal“ sounds:
3. Close battery compartment. Wait until the error message „BAT-CMP
OPEN“ reappears again.
4. Confirm the error message by entering the current Master Code (de-
fault:
00123456
) with the
<NUMERIC>
keys, then press the
<ENTER>
key. The lock opens and closes again after approx. 6 seconds.
5. Fix battery compartment with hexagon countersink screw.
Important!
If during wiring test the error message „LINE OFF“ continuously appears, the
connection cable is either connected incorrectly or it was damaged during
installation. Do not continue installation and proceed as follows:
• Check connection cable for correct connection or damage. Disconnect con-
nection cable and replace if necessary.
• Reconnect connection cable as described in sections
Installing the Input
Unit on page 20 and Installing the lock on page 25.
• Check whether new batteries were inserted. If not, insert new batteries.
If another error message appeared please refer to section
Error messages
on page 101.