5.6 Buzzer
signals
Buzzer signal
Display
Cause
1 short beep
Key stroke
1 short, low-frequency
beep
REFUSED
Action refused
1 short beep
every 60 seconds
WAIT
Time Delay or Duress Time
Delay active
3 short beeps
every 60 seconds
CONF
Confirmation Window active
(waiting for confirmation
code after elapse of Time
Delay)
10 short beeps
every 10 seconds
BAT-CMP
OPEN
Battery compartment has
been opened
10 short beeps
every 30 seconds
OPEN
Lock open
AS284-USBW or AS284-NETW Programming Software
• Buzzer signal during „OPEN“ (lock open), during „WAIT“ (Time delay) and
during „CONF“ (Confi rmation window) can be deactivated.
• Buzzer volume may be set to „high“, „low“ or „off“.
5.7 Status
messages
During operation, the following status messages can be shown. Status
messages in bank mode (standard mode) are indicated with “S”; status
messages in interactive mode (OTM) with “I”:
5.7.1 Locked (mode S)
The lock is mechanically closed – the current time is dis-
played. It may be opened by entering a valid code.
5.7.2
Locked (mode I)
The lock is mechanically closed and awaits the identifi-
cation of a user (entry of a 4 digit user ID).
The current time may be displayed (configurable with
AS284-USBW or AS284-NETW).