5.10
Opening
procedure
Note!
Opening is not possible during following conditions:
• Penalty after wrong trials (
page 41).
• During active Locking Period (Immediate, Weekly, Holiday) (
page 62).
• While the battery compartment is open (
page 42).
• During Remote Disabling is in process (
page 41).
• Active connection with the Programming Software (
page 42).
• During Non Return Time Delay (
page 41).
5.10.1
Opening procedure in bank mode
The Display switches off automatically after 1 minute without any key be-
ing pressed.
1. Press any key to wake up the display (if necessary). The lock status ap-
pears.
2. Key-in the Code (e.g. 11123456) using the
<NUMERIC>
keys (an asterisk
appears for every digit entered). Press the
<ENTER>
key to confirm the
Code.
3. If unit is set to Dual Mode enter second code as described above. Press
the
<ENTER>
key to confirm the Code.