OM_Axessor_CIT_V024_20170518_EN.pdf Operating
Manual
Page 64
Subject to change without prior notice
Axessor CIT
6. Use
the
<LEFT>
or
<RIGHT>
key to set the day (
note below step
5)
and the time of the
end point of the Locking Period
(indicated by the
„
lock open
” symbol).
7. Press
the
<ENTER>
key to confirm the setting in the upcoming save
dialogue.
8. Repeat steps 2 to 7 to define other Locking Periods or press the
<Info/
Esc>
key to exit the function.
Note!
• Weekly Locking Periods can last 1 minute to 6 days, 23 hours and 59 min-
utes.
• Between two Weekly Locking Periods opening must be possible. Therefore
the time gap must be larger than: the defi ned Time Delay (or Duress Time
Delay, if larger) + the Confi rmation one additional minute.
• Weekly Locking Periods are saved in chronological order, starting with Mon-
day.
• The AS284-USBW or AS284-NETW can confi gure, that time Lock applies for
OTM codes as well.
6.4.2.2.2 Modifying an existing Weekly Locking Period
Proceed as described for adding a new Weekly Locking Period (
Adding
a Weekly Locking Period on page 63
). Instead of pressing the
<ENTER>
key in step 3 use the
<LEFT>
or
<RIGHT>
key to select the Weekly Locking
Period you wish to alter and overwrite it.
6.4.2.2.3 Deleting an existing Weekly Locking Period
1. Select submenu „WEEKLY“.
2. Press
the
<ENTER>
key. The starting point of the first defined Weekly
Locking Period is displayed.
3. Use
the
<LEFT>
or
<RIGHT>
key to select the starting point of the
Weekly Locking Period (indicated by the „
lock closed
” symbol) you wish
to delete.
4. Press
the
<DEL>
key.
5. In the upcoming delete dialogue select „
YES
“ using the
<LEFT>
or
<RIGHT>
key, then press the
<ENTER>
key. The corresponding Locking
Summary of Contents for Axessor CIT