Period will be deleted.
6.4.2.3 Configuring Holiday Locking Periods - Submenu HOLIDAY
This function permits defining of up to 22 date-related time windows,
during which the lock cannot be opened (e.g. during holidays or on public
holidays).
Authorization: Master
Code
6.4.2.3.1 Adding a Holiday Locking Period
1. Select submenu „HOLIDAY“.
2. Press
the
<ENTER>
key. If any Holiday Locking Periods are already
defined, the count is displayed.
3. Press
the
<ENTER>
key to enter a new period.
4. Use
the
<LEFT>
or
<RIGHT>
key to set the day and the year of the
starting point of the Holiday Locking Period
(indicated by the „
lock
closed
” symbol) and the
<ENTER>
key for confirmation.
Note!
If the maximum of 22 Holiday Locking Periods are already defi ned upon press-
ing the „ENTER“ key the display does not change / react.
5. Press
the
<ENTER>
key.
6. Use
the
<LEFT>
or
<RIGHT>
key to set the day and the year of the
end
point of the Holiday Locking Period
(indicated by the „
lock open
” sym-
bol).
7. Press
the
<ENTER>
key to confirm the settings in the upcoming save
dialogue.