TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, under no circumstances shall
SmartPro, its manufacturer or any of its subsidiaries, licensors, distributors, resellers, servants
and/or agents be responsible for any special, incidental, consequential or indirect damages
howsoever caused.
The tester or SmartPro Finder I (SPF I) referred to in this user manual is provided and/or sold on
an “as is” basis. Except as required by applicable law, no warranties of any kind, either expressed
or implied, including, but not limited to, the implied warranties of merchantability and fitness for a
particular purpose.
Place the gemstone on the metal stone tray and it with one hand while holding the tester with the
other hand
(Fig.2.2).
26
5
7
CONTENTS
I. Disclaimers, Exclusions and Limitations of Liability
II. About the SmartPro Finder I
III. IMPORTANT NOTICE
1. GETTING STARTED with SmartPro Finder I
2. PERFORMING TEST with SmartPro Finder I
3. READING TEST RESULT on SmartPro Finder I
4. TAKING CARE of your SmartPro Finder I
04
06
10
12
24
27
28
a. High efficiency diamond tester
b. Retractable thermoelectric probe tip that ensures constant pressure between probe tip and
gemstone
c. Industry’s thinnest probe tip (0.48mm) for testing diamonds as small as 0.01ct
d. Diamond indicator LED blinking with sound
e. Metal detection indicator LED alarm with ringing sound.
f. Simulant indicator LED
g. Low battery indicator LED
h. No waiting time between tests
i. Super Clear & Bright LED display
j. Automatically power-off within 2 minutes (Sleep mode)
k. Powered by AAA batteries (x2)
The SmartPro Finder I features the following:
For testing loose gemstones
ME
TA
L
SI
MU
LA
NT
DAIMON
D
Fig. 2.2
24
For mounted jewelry or gemstones
2. PERFORMING A TEST with SmartPro Finder I
Hold the jewelry or gemstone with one hand and the tester with other hand
(Fig.2.1)
. For proper
operation of the tester, the thumb and index finger must always be placed on the metal-plated
serrated part located on both sides of the tester at all times. Care should be taken when testing
mounted jewelry. User must ensure that the stones are securely mounted before conducting a test
as gap between stone an setting might lead to inaccurate reading.
Place the tip of the probe pen against the gemstone. Apply minimal pressure to fully depress the
tip into the probe pen for correct reading. This is to provide a steady and constant contact made
between the probe tip and the gemstone.
22
Battery information
Do not leave worn out batteries in the battery compartment as the batteries may corrode, leak,
and damage the tester. Batteries should be removed when the tester is expected to be store for
an extended period of time.
To prevent inaccurate readings, replace with new battery as soon as the “Low Battery” indicator
LED is blinking and become faster when battery near to empty.
20
Fig. 1.2
9
11
13
Composition
1. Retractable probe tip
2. Serrated Metal Part
3 “Ready” Indicator LED
4. “Low Battery” Indicator LED
5. “Metal” Indicator LED
6. “Simulant” Indicator LEDs
7. “Diamond” Indicator LED
8. ON/OFF Button Switch
9. Battery compartment
10. Neck Strap Attachment
11. Probe Protective Cap
f. Do not drop, knock, or shake the tester. Rough handling can break internal circuit boards and
fine mechanics.
g. Do not use harsh chemicals, cleaning solvents, or strong detergents to clean the tester.
h. Do not paint the tester. Paint can clog the moving parts and prevent proper operation.
If the tester is not working properly, kindly contact our customer service at
customercare@smartproinstrument.com
SmartPro Instrument co.,ltd
249/40, Moo 9, J.S.P. Building
Bangbon 1 Rd., Bangbon
Bangkok 10150 Thailand
+66 (0) 2 899 2956-7
Attn: Customer Service Executive
Turning on
Remove the protective cover from the probe tip
(Fig. 1.2).
Prepare clean tissue / jewelry cloth. Carefully retrieve the gemstone with tweezers and place the
gemstone face down the table
(Fig.1.7).
Cleaning your gemstone prior to testing
Fig. 1.7
The gemstone should be clean and dry before testing. However, elaborate cleaning procedures
are not normally necessary
(Fig.1.6).
18
Recommended testing conditions
Fig. 1.6
Cleaning the probe tip
Please note that if the tester is being used for the first time, or if the tester has not been used for
a week, it is advisable to clean the probe tip using an oxidation removal sheet to attain consistent
and accurate reading.
b. Hold the probe pen with pen tip forming the right angle (90 degree) with an oxidation removal.
Gently move in a circular motion without retracting the tip
(Fig. 1.5)
.
16
a. Ensure the unit is switched off.
c. Repeat the same motion several times. The cleaning process is completed and tester is now
ready for use.
11
1
2
3
6
8
10
4
7
9
5
24