4
WIRING –
(Check off box when complete)
** Refer to the Appendix for the following connections **
Power –
(Sheet 3: Machine Room connections)
Connect main line power to terminal block L1/L2/L3.
Connect the ground wire to the yellow/green terminal block
next to L1-L3.
Brake –
(Sheet 5: Brakes)
Connect the main brake wiring to terminals K1 / K2 and the
secondary brake wiring (if equipped) to terminals J1 / J2 located
on the terminal block next to the M contactor.
Jump EB to the terminal listed in the Construction box located
on “Sheet 01 – Getting Started” and connect either the rope
gripper or shieve brake to EBR (if installed).
Motor / Encoder –
(Sheet 4: Drive and Motor)
Connect motor leads to the M contactor at T1/T2/T3.
Connect the encoder cable to the PG Card located under the top
cover. The following table contains wiring references for
common encoders.