READ AND FOLLOW
ALL INSTRUCTIONS!!
T
HIS
UNIT
IS
A
PROFESSIONAL
-
GRADE
PRODUCT
. A
KNOWLEDGE
OF
CONSTRUCTION
TECHNIQUES
,
PLUMBING
AND
ELECTRICAL
INSTALLATION
ACCORDING
TO
CODES
ARE
REQUIRED
FOR
PROPER
INSTALLATION
AND
USER
SATISFACTION
. I
T
IS
RECOMMENDED
THAT
A
LICENSED
CONTRACTOR
PERFORM
THE
INSTALLATION
. W
ARRANTY
IS
VOIDED
FOR
IMPROPER
I
NSTALLATION
RELATED
ISSUES
.
I
T
IS
THE
RESPONSIBILITY
OF
THE
HOME
OWNER
TO
ENSURE
THAT
ALL
USERS
OF
THE
SPA
ARE
ADEQUATELY
INFORMED
OF
ALL
PRECAUTIONS
.
U
SE
THE
SPA
ONLY
AS
DESCRIBED
IN
THIS
MANUAL
. T
HE
SPA
IS
INTENDED
FOR
HOME
USE
ONLY
. D
O
NOT
USE
THE
SPA
IN
A
COMMERCIAL
OR
RENTAL
SETTING
. A
LL
WARRANTIES
WILL
BE
VOIDED
.
GROUND ALL METAL ELECTRICAL EQUIPMENT
•
A
GREEN
COLORED
TERMINAL
OR
A
TERMINAL
MARKED
G, GR, G
ROUND
,
OR
G
ROUNDING
,
IS
LOCATED
INSIDE
THE
SUPPLY
TERMINAL
BOX
OR
COMPARTMENT
. T
HIS
TERMINAL
MUST
BE
CONNECTED
TO
THE
GROUNDING
MEANS
PROVIDED
IN
THE
ELECTRIC
SUPPLY
SERVICE
PANEL
,
USING
A
CONTINUOUS
COPPER
WIRE
EQUIVALENT
IN
SIZE
TO
THE
CIRCUIT
CONDUCTORS
SUPPLYING
THIS
EQUIPMENT
.
*
ACCORDING
TO
,
BUT
NOT
LIMITED
TO
: NEC, NFPA 70, S
ECTION
680.40, UL 1563.
•
A
T
LEAST
TWO
LUGS
MARKED
“B
ONDING
L
UGS
”
ARE
PROVIDED
ON
THE
EXTERNAL
SURFACE
OR
ON
THE
INSIDE
OF
THE
SUPPLY
TERMINAL
BOX
OR
COMPARTMENT
. C
ONNECT
THE
LOCAL
COMMON
BONDING
GRID
(
HOUSEHOLD
GROUND
)
IN
THE
AREA
OF
THE
SPA
TO
THESE
TERMINALS
,
USING
AN
INSULATED
OR
BARE
COPPER
CONDUCTOR
NOT
SMALLER
THAN
N
O
. 6 AWG.
•
A
LL
FIELD
-
INSTALLED
METAL
COMPONENTS
SUCH
AS
RAILS
,
LADDERS
,
DRAINS
OR
SIMILAR
HARDWARE
LOCATED
WITHIN
5
FEET
OF
THE
SPA
OR
HOT
TUB
MUST
BE
BONDED
TO
THE
EQUIPMENT
GROUNDING
BUS
WITH
COPPER
CONDUCTORS
NOT
SMALLER
THAN
N
O
. 6 AWG.
•
A
LL
METAL
SURFACES
WITHIN
5
FEET
OF
THE
SPA
MUST
BE
BONDED
TO
THE
HOME
BONDING
GRID
.
GROUND FAULT CIRCUIT INTERRUPTER PROTECTION
(OR EQUIVALENT; RCD, FOR EXPORT INSTALLS)
•
A
LL
PDC S
PAS
ARE
PERMANENTLY
INSTALLED
UNITS
. GROUND FAULT CIRCUIT INTERRUPTER
PROTECTION IS REQUIRED. A
LL
SPA
EQUIPMENT
SYSTEMS
MUST
BE
PROTECTED
BY
A
CLASS
A
GROUND
FAULT
CIRCUIT
INTERRUPTER
(GFCI)
OR
EQUIVALENT
; RCD,
FOR
EXPORT
INSTALLS
. A
GROUND
FAULT
CIRCUIT
INTERRUPTER
TYPE
CIRCUIT
BREAKER
(NOT SUPPLIED)
MUST
BE
INSTALLED
IN
THE
HOME
PANEL
BOX
BY
A
LICENSED
ELECTRICIAN
WHEN
MAKING
WIRE
CONNECTION
TO
THE
SPA
SUPPORT
PACK
EQUIPMENT
.
DANGER: RISK OF ELECTRICAL SHOCK:
•
I
NSTALL
THE
SPA
AT
LEAST
FIVE
FEET
(1.52
M
)
FROM
ALL
UNGROUNDED
(
UNBOUNDED
)
METAL
SURFACES
.
•
G
ROUND
FAULT
CIRCUIT
INTERRUPTER
PROTECTION
OF
THE
HOME
POWER
SUPPLY
TO
THE
SPA
IS
NECESSARY
. Y
OUR
ELECTRICIAN
SHOULD
EXPLAIN
HOW
IT
WORKS
. (S
EE
SPA
MAINTENANCE
)
•
D
O
NOT
PERMIT
ANY
ELECTRIC
APPLIANCE
,
SUCH
AS
A
LIGHT
,
TELEPHONE
,
RADIO
OR
TELEVISION
,
WITHIN
FIVE
FEET
(1.52
M
)
OF
A
SPA
. K
EEP
ELECTRICAL
APPLIANCES
AND
EXTENSION
CORDS
AWAY
FROM
THE
SPA
. W
ATER
IS
A
CONDUCTOR
OF
ELECTRICITY
.
READ AND FOLLOW ALL IMPORTANT SAFETY INSTRUCTIONS
W
HEN
INSTALLING
AND
USING
THIS
EQUIPMENT
BASIC
SAFETY
PRECAUTIONS
SHOULD
ALWAYS
BE
TAKEN
TO
REDUCE
THE
RISK
OF
ELECTRICAL
SHOCK
,
TO
ENSURE
SAFE
USAGE
,
AND
TO
SAFEGUARD
THE
USER
’
S
HEALTH
.
S
AFETY
I
NSTRUCTIONS
2