ASSEMBLE FRONT PANEL
10
SELECT:
2 x 1.980 Wall Sheets
1 x 2.020 Top Plate (Red)
1 x 2.020 Bottom Plate (Green)
2 x 1.980 Door Jamb Flashings
28 x 30mm Galv Clouts
17 x Rivets
STEP 1:
•
Lay out 1 x Top Plate and 1 x Bottom Plate on a flat surface
as shown.
STEP 3:
•
Place 2x Wall Sheets on timber, ensuring wall sheets fit under-
neath door jamb flashings.
•
Ensure that the top of the sheet is flush with the top of the Top
Plate and that the sides of the wall sheets overhang the Top
Plate by
15mm
as shown. Nail wall sheets to Top Plate (two
clouts per pan)
•
Nail the wall sheets to the Bottom Plate making sure that the
Plates are the correct distance apart and that the sides of the
wall sheet overhang the Bottom Plate by
15mm
.
•
Drill & rivet Door Jamb Flashings to wall sheets using four riv-
ets equally
IMPORTANT—IF YOU CHOOSE TO RAISE YOUR TIMBER
BASE PLATE –READ THE FOLLOWING;
For sheds with Raised Base Plate option only (see page 6), deduct
30mm from measurement shown between Top and Bottom Plates on
all wall panels, so cladding protrudes 20mm below bottom plate
.
15mm
15mm
15mm
15mm
TOP
PLATE
DOOR
JAMB
NAIL
x3
x3
x3
530mm
960mm
TOP PLATE
DOOR OPENING
Plan View
STEP 2:
•
Using 2 x 30mm clouts, nail the Door Jamb Flashing flush
with the top of the Top Plate at the correct measurement as
shown in plan view. Pre drill holes using a 3.5mm drill bit
•
Check the distance between the top and bottom plates then
use a further 2 x 30mm clouts to nail the Door Jamb Flashings
to the bottom Plate. Pre drill holes.
STEP 4:
•
Place the door on the panel (In open position, approx 20mm
below top of top plate). Using two rivets, rivet the top and bot-
tom hinges to the Door Jamb Flashing, ensuring door closes
properly.
•
Fit remaining rivets.
NOTE:
Door can be hinged on either side.
BOTTOM PLATE
1948mm
TOP PLATE
1948mm