25
SVC400P/SVC800P - User Manual
NORMAL REC RATE:
normal record rate, two option:
o
NORMAL:
DVR will start to record according to the setup of RECORD SETTING.
o
I FRAME:
DVR only record at 1 frame in order to take less space of hard drive. BUT when
event is trigged, DVR will record according to setup of RECORD SETTING.
ALARM PRE-REX TIME (1-60) MIN:
pre-record time setting from 1 to 60 minutes. For example: If the
setting for pre-record is 30 min, when alarm trigger at 10:30, then the record file start from 10:00 to 10:30
will pack as alarm record.
ALARM DURATION (3-30) EC:
the alarm duration time, All the alarm for same type considered to be
one alarm during the setting for alarm duration and DVR reset the duration time automatically. For
example, if the setting for alarm duration is 10 sec and during this 10 sec, anther same type alarm
triggered and then DVR system will consider them to be one alarm event. And the alarm start time will be
reset based on the second time for alarm.
ALARM POST REC (30-1800) SEC:
alarm post recording time setting.
BUZZER ALARM TIME:
buzzer alarm duration time setup, when alarm triggered, the buzzer duration
time.
MEDADATA CAPTURE:
metadata information
M.D. REC. WHEN IGNITION OFF:
Active the Motion Detection function when the ignition is OFF.
MIRROR REC.TO SD CARD:
Active Mirror function. SD card and HDD can record at the same time.
HDD record based on high resolution, but SD card can record by lower resolution. Mirror function is for
backup. When the HDD is broken, you can also search the video files from SD card.
RECORD FILE TIME (MIN):
recording file packing size, 15, 30,45,60 minutes optional
HDD/SD OVERWRITE:
To make the HDD overwrite when there is only 2GB space in HDD.
o
ON:
when hard drive space less than 2G, according to
“First in first out” rule, system will start to
delete the earliest record files till HDD space equal or over 10G (except the alarm file which in
locked time).
o
OFF:
Device will stop recording when hard drive space is full (less than 500M), you must replace an
HDD or delete recording file manually, then it will start to record.
LOCKED FILE RETENTION (DAY):
Locked recording file save time: 7, 10, 15, 20, 30, 45 days optional,