HRX-OM-W058
Chapter 5 Display and setting of various functions
HRS-R Series
5.19
Communication function
5-59
26.
Select response delay time (simple communication protocol) from the table below with
[▲] key or [▼] key, and confirm by pressing “SEL”.
Table 5.19-14
List of set value
Set value
Explanation
Initial value
(Default setting)
Setting/checking are not available unless the
serial
protocol
setting
is
simple
communication protocol.
to
Setting of response delay time.
Set range is 0 to 250msec.
Communication range (simple communication protocol) Setting and checking
27.
Press the [SEL] key once.
The set screen of communication range (simple communication protocol) is displayed
on the digital display.
28.
Select communication range (simple communication protocol) from the table below with
[▲] key or [▼] key, and confirm by pressing “SEL”.
Table 5.19-15
List of set value
Set value
Explanation
Initial value
(Default setting)
Setting/checking are not available unless the
serial
protocol
setting
is
simple
communication protocol.
Only reading is available
Reading and writing are available
○
Contact input signal 1 Setting and checking
29.
Press the [SEL] key once.
The set screen of contact input signal 1 is displayed on the digital display.
PV
SV
PV
SV