- 15 -
3.2.4 Source I/O interfaces
In this driver, source type I/O interfaces can be used. In this case, all DI-1 input signals and DO-1 output signals are of
source type. Perform wiring according to the following interfaces.
(1) Digital input interface DI-1
Servo amplifier
Switch
Approx. 5mA
V
CES
1.0V
I
CEO
100 A
24VDC 10
300mA
Approx. 5.6k
SON,
etc.
DICOM
(2) Digital output interface DO-1
A maximum of 2.6V voltage drop occurs in the driver.
(Note)
If polarity of diode is
reversed, servo
amplifier will fail.
24VDC 10
300mA
Servo amplifier
ALM,
etc.
Load
DOCOM
Note. If the voltage drop (maximum of 2.6V) interferes with the relay operation, apply high voltage (up to 26.4V) from
external source.
4. Parameter list for each mode
Parameters require setting. If necessary, please set the parameters.
Refer to "LECSB
Operation Manual”, chapter 5 and "LECSB Operation Manual (Simplified Edition)”, section 5.3
for details.
Refer to "LECSB Operation Manual", chapter 5 for parameters which are not mentioned in this clause.
Setup software
(MR Configurator2
TM
: LEC-MRC2E) is necessary for the setting of parameter.
*1 Setup software version 1.52E or above is required.
*2 The setup software (MR Configurator2
TM
: LEC-MRC2E) must be purchased as an additional item.
*3 The USB cable (LEC-MR-J3USB) must be purchased as an additional item.
Driver
Driver
driver