- 40 -
5.5.2 Initial I/O Signal Allocation
The initial (Default) allocation of I/O signals is shown below.
Input signal points (10): (position control mode) and initial assignment
Output signal points (6) (position control mode) and initial assignment
See “LECSB Operation Manual”, section 3.5 for details regarding signals.
See “LECSB Operation Manual”, section 5.4 for parameter configuration values.
5.5.3 Signal Allocation using Setup Software
①
The
“Parameter Setting” window will be displayed when “Parameter Setting” is selected from the “Parameter”
menu in the setup software.
②
Click the I/O tab.
③
When changing the allocation of signals, parameters for “PD03” - “PD08”, “PD10” - “PD16” or “PD18” can be
altered.
PD03 to PD12 Input signal assignment (CN1-15 to CN1-19, CN1-41, CN1-43 to CN1-45)
PD13 to PD18 Output signal assignment (CN1-22 to CN1-25, CN1-49)
③
②