C
OMPLIANCES
v
EC Conformance Declaration - Class B
This information technology equipment complies with the requirements of the Council
Directive 89/336/EEC on the Approximation of the laws of the Member States relating to
Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain
voltage limits and the Amendment Directive 93/68/EEC. For the evaluation of the
compliance with these Directives, the following standards were applied:
RFI Emission:
• Limit class B according to EN 55022:1998
• Limit class B for harmonic current emission according to
EN 61000-3-2/1995
• Limitation of voltage fluctuation and flicker in low-voltage supply
system according to EN 61000-3-3/1995
Immunity:
• Product family standard according to EN 55024:1998
• Electrostatic Discharge according to EN 61000-4-2:1995
(Contact Discharge: ±4 kV, Air Discharge: ±8 kV)
• Radio-frequency electromagnetic field according to EN 61000-4-3:1996
(80 - 1000 MHz with 1 kHz AM 80% Modulation: 3 V/m)
• Electrical fast transient/burst according to EN 61000-4-4:1995 (AC/
DC power supply: ±1 kV, Data/Signal lines: ±0.5 kV)
• Surge immunity test according to EN 61000-4-5:1995
(AC/DC Line to Line: ±1 kV, AC/DC Line to Earth: ±2 kV)
• Immunity to conducted disturbances, Induced by radio-frequency
fields: EN 61000-4-6:1996 (0.15 - 80 MHz with
1 kHz AM 80% Modulation: 3 V/m)
• Power frequency magnetic field immunity test according to
EN 61000-4-8:1993 (1 A/m at frequency 50 Hz)
• Voltage dips, short interruptions and voltage variations immunity test
according to EN 61000-4-11:1994 (>95% Reduction @10 ms, 30%
Reduction @500 ms, >95% Reduction @5000 ms)
LVD:
• EN 60950 (A1/1992; A2/1993; A3/1993; A4/1995; A11/1997)
Summary of Contents for 7404BRA FRT
Page 2: ......
Page 7: ...COMPLIANCES vi ...
Page 11: ...TABLE OF CONTENTS iv ...
Page 25: ...CONFIGURING CLIENT PCS 3 2 ...
Page 62: ...FIREWALL 4 37 Access Control Add PC ...
Page 65: ...CONFIGURING THE BARRICADE 4 40 3 Click OK and then click APPLY to save your settings ...
Page 66: ...FIREWALL 4 41 Intrusion Detection ...
Page 75: ...CONFIGURING THE BARRICADE 4 50 Status ...
Page 83: ...CONFIGURING THE BARRICADE 4 58 ...
Page 107: ...CONFIGURING CLIENT TCP IP 5 24 ...
Page 115: ...CONFIGURE THE PRINT SERVER 6 8 ...
Page 119: ...TROUBLESHOOTING A 4 ...
Page 125: ...CABLES B 6 ...