C
OMPLIANCES
vi
• This unit operates under SELV (Safety Extra Low Voltage) conditions according to
IEC 60950. The conditions are only maintained if the equipment to which it is connected
also operates under SELV conditions.
France and Peru only
This unit cannot be powered from IT
†
supplies. If your supplies are of IT type, this unit must
be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary
connection point labelled Neutral, connected directly to earth (ground).
†
Impédance à la terre
Important!
Before making connections, make sure you have the correct cord set. Check it
(read the label on the cable) against the following:
Power Cord Set
U.S.A. and Canada
The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:
- No. 18 AWG - not longer than 2 meters, or 16 AWG.
- Type SV or SJ
- 3-conductor
The cord set must have a rated current capacity of at least 10 A
The attachment plug must be an earth-grounding type with NEMA
5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V) configuration.
Denmark
The supply plug must comply with Section 107-2-D1, Standard
DK2-1a or DK2-5a.
Switzerland
The supply plug must comply with SEV/ASE 1011.
U.K.
The supply plug must comply with BS1363 (3-pin 13 A) and be
fitted with a 5 A fuse which complies with BS1362.
The mains cord must be <HAR> or <BASEC> marked and be of
type HO3VVF3GO.75 (minimum).
Europe
The supply plug must comply with CEE7/7 (“SCHUKO”).
The mains cord must be <HAR> or <BASEC> marked and be of
type HO3VVF3GO.75 (minimum).
IEC-320
socket
.
Summary of Contents for 8612T2 FICHE
Page 2: ......
Page 18: ...TABLE OF CONTENTS x ...
Page 26: ...ABOUT THE TIGERSWITCH 10 100 1000 1 8 ...
Page 42: ...INSTALLING THE SWITCH 3 8 ...
Page 62: ...ORDERING INFORMATION D 2 ...
Page 68: ...Glossary 6 ...
Page 72: ...INDEX Index 4 ...
Page 73: ......