Chapter 4: Specifications

 

Product Multi-counter 

Mounting 

Surface mount (with DIN rail or set screws) 

Operation Addition and subtraction 

Mode 

Operation mode, Preset data setting mode, Function setting mode 

Reset 

External reset terminal 

Indication 

LCD (with back-light) 

Digits 6 

digits 

Memory Backup 

{medium} 

Set values (Constantly hold), counts (hold/ non-hold switching) 

{E

2

 ROM (alarm indication at approx. 800,000 data writings)} 

Input signal 

Count input, control signal input (reset, hold, bank selection) 

Count Input 

No-voltage input 

Pulse signal input 

A/B quadrature input, UP/ DOWN individual pulse input (Note 1) 

Counting speed 

100 kHz (Note 2) 

Control signal input 

"For connecting COM terminal to 12VDC or 24VDC" 
 

Conduction between each input terminal and GND terminal.   

"For connecting COM terminal to GND terminal" 
 

Conduction between each input terminal and 12VDC or 24VDC terminal. 

power supply for sensor 

12VDC 

±

10%, 60 mA 

Preset output form 

Compare, hold, one-shot (fixed at 100 ms) 

Output method 

Individual 5 points output, binary code output 

Output time lag 

5 ms or less (in normal output)/

 

60ms or less (in binary output) 

Communication RS-232C 

Proof voltage 

Between case and AC line: 1500 VAC, 1 minute 

Between case and signal earth: 500 VAC, 1 minute 

Insulation resistance 

Between case and AC line: 500 VDC, 50M

Ω

or more 

Ambient temperature 

0

  to + 50

 (No freezing) 

Ambient humidity 

35% to 85%RH (no dew condensation) 

Noise resistance 

 

Square wave noise by noise simulator (pulse width: 1

μ

s) 

Between power terminals: 

±

2000V, input line: 

±

600V 

Vibration proof 

Durable to 10 Hz to 55 Hz and amplitude of 0.75 mm in X, Y and Z directions 

for 2 hours each. 

Impact resistance 

Durable to 10 G in X, Y and Z directions for three times each. 

Weight 

Approx. 350 g 

 

 

CEU5

*-* (Without "B")

 CEU5

*

B

-*

 

Output signal 

Preset output , cylinder stop output 

Preset output , cylinder stop output , 

BCD output 

 

 

CEU5

*-* (Without "P")

 CEU5P

*-*

 

Output transistor type

 

NPN open collector 

(Max.30VDC,50mA)

PNP open collector 

(Max.30VDC,50mA)

 

 

CEU5

**

 CEU5

**-

Power voltage

 

100VAC to 240VAC (

±

10%)

24VDC (

±

10%) 

Power consumption

 

20VA or less 

10W or less 

Note 1: Pulse signals can be counted by CEU5 should meet “Input waveform requirements” in the next 

page. 

Note 2: Counting speed of 100 kHz is provided when “Input waveform requirements” are met.    When 

signals are 

damped due to long wires, taking countermeasures such as reducing the speed 

is required.

 

 

 

 

Summary of Contents for CEU5

Page 1: ...060 C OPERATION MANUAL PRODUCT NAME Multi counter MODEL CEU5 z READ THIS OPERATION MANUAL CAREFULLY BEFORE USE IT z NEVER INSTALL THE PRODUCT UNTIL FINISH READING THIS z KEEP THIS MANUAL ALL THE TIME...

Page 2: ...1 1 Mode types and functions 14 7 1 2 Mode switching procedure 14 7 1 3 Setting of function mode 15 7 1 4 Data setting range 16 7 2 Setting 17 7 3 Counter operation 21 7 3 1 Handling data range 21 7...

Page 3: ...cations and possibilities of failures by checking the latest product information 2 Only trained personnel should operate pneumatically operated machinery and equipment Assembly handling or repair of p...

Page 4: ...with devices generating strong electromagnetic noise 4 Separation of signal wires from power wire Avoid common or parallel wiring of signal and power wires to prevent malfunction due to noise 5 Check...

Page 5: ...are expected k Place where vibration or impact is directly given to the products l Condition that the products are deformed by force or weight applied Operation Warning 1 Terminal block protective co...

Page 6: ...allows this counter to send counts to PC PLC and set the counter by communications with PLC PC For the counter with BCD output counts can be sent to PC PLC by BCD coding 2 1 How to Order Eight variat...

Page 7: ...ver No 21 through No 31 can be used only for binary output Normal output Binary output Features Allocate one output terminal to one preset number Divide preset numbers of 1 through 20 into four blocks...

Page 8: ...utput and UP DOWN individual pulse output 3 Pre scale function Function for the user to optionally set the number indicated for one count 4 Setting of tolerances for preset values Upper and lower limi...

Page 9: ...when the hold signal is inputted can be taken in The display is held however counting is continued inside At this time preset output is sent out according to the count inside with or without hold sign...

Page 10: ...t 60ms or less in binary output Communication RS 232C Proof voltage Between case and AC line 1500 VAC 1 minute Between case and signal earth 500 VAC 1 minute Insulation resistance Between case and AC...

Page 11: ...e 100 kHz and the waveforms of UP and DOWN pulses are as below C B A 12V 10 12V 10 Channel A UP pulse Channel B DOWN pulse requires 5 sec or more requires 5 sec or more requires 5 sec or more Not appl...

Page 12: ...No Preset No Multiplication Upper limit Function items PRESCL OFFSET STOP OUTPUT INPUT BACKUP RS232C UNIT Mode indication Counts Preset values Count value per pulse Offset setting Cylinder stop outpu...

Page 13: ...tput block terminals for preset output and cylinder stop output Serial transmission block terminals for RS 232C communication A phase pulse input DOWN pulse Caution The COM terminal of each block is i...

Page 14: ...ut The following shows the wiring for preset output OUT 1 through 5 and cylinder stop output S STOP with two output types NPN and PNP Model Wiring CEU5 CEU5B CEU5 D CEU5B D NPN transistor open collect...

Page 15: ...s in wiring 4 When cables may cause radiation noise mount a ferrite core on a signal cable 5 Use another stable power source for CEU5 power supply separate from motor and solenoid valve for AC type 6...

Page 16: ...cylinder stop output output type input type backup RS 232C and unit No 7 1 2 Mode switching procedure Mode can be switched by MODE key all the time The initial mode when turning ON the power is count...

Page 17: ...nal when pulse signals from Monosashi kun encoder do not change for a certain period of time This output signal provides better timing for reading preset output and outputs sent to PLC PC Setting Inpu...

Page 18: ...3 Upper limit 999999 to 999999 000000 4 Lower limit 999999 to 999999 000000 Preset 5 Preset output form 1SHOT HOLD COMPARE 1SHOT 1 Pre scale Connecting model CEP1 CE1 MANUAL CEP1 Multiplication 1 2 4...

Page 19: ...etting z Move digits by LEFT RIGHT key Increase or decrease numerical values by UP DOWN key z Move on to the next item by SEL key SEL Upper limit setting z Set numerical values by direction keys z Whe...

Page 20: ...2 or 4 by UP DOWN key 4 indicates a four quadrant z Move onto the next item by SEL key Setting of pre scale value z Set the unit per count z Move digits by LEFT RIGHT key Increase or decrease numeric...

Page 21: ...NC Counts backup 7 6 z Select A B quadrature input 2PHASE or indi vidual pulse input UP DOWN by UP DOWN key When polarity is changed counter directions are reversed 2PHASE UP Down 2PHASE UP Down z Sto...

Page 22: ...t setting DOWN Change the setting Decrease numerical values at setting z Direction keys in operation procedure indicate four keys UP DOWN LEFT and RIGHT 9 z Move digits by LEFT RIGHT key Increase or d...

Page 23: ...munication or BCD output The display on the counter is held during a hold signal is coming in With RS 232C communication or BCD output the data indicated is sent out Even if reading process of the PLC...

Page 24: ...output is ON Preset values can be stored up to 31 points However No 21 to 31 are only active in binary output and their preset output form is fixed at COMPARE mode 7 3 5 Output 1 Output form can be s...

Page 25: ...ard Count direction Preset value Output is ON for 100ms when a count crossed the preset value allowance When moved toward When moved toward Count direction Preset value Allowance HOLD HOLD is indicate...

Page 26: ...Reset if a measurement is taken with this position as a basis The above chart is an example when the settings of No 1 through 5 are as in the table below With normal output and bank 1 selection No 1 N...

Page 27: ...t processing time takes 300 ms and it will be longer for longer reset signal input time Reset input time 10 ms to 100 ms Longer reset input time Reset processing time ms 10 100ms Reset signal ON Reset...

Page 28: ...tput setting Stored in E2 ROM when settings are z Output type setting changed z Input type setting z Backup setting z RS 232C setting z Unit No setting z Digital filter setting z Current counts Only w...

Page 29: ...ata PR Reading pre scale setting PW Writing pre scale setting FR Reading indication offset setting FW Writing indication offset setting SR Reading cylinder stop output setting SW Writing cylinder stop...

Page 30: ...stead response block EE command containing error code is sent back The values set in setting mode by communication are stored in E2 ROM Since E2 ROM has the life of 1 000 000 times avoid unintentional...

Page 31: ...in HOLD inputting Indication overflow Indication underflow Counter overflow reset is required 5 Communication format details Reading counts VR Command Block 0 0 V R CR Unit No Command Check sum code...

Page 32: ...mit Allowance lower limit Output form O H C Writing preset data Command Block 0 0 D W CR Unit No Command Preset No Command Check sum code data Command data details 3 3 3 3 3 3 1 1 1 1 1 1 2 2 2 2 2 2...

Page 33: ...1 1 Multiplication Pre scale value Decimal point position Writing pre scale setting Command Block 0 0 P W CR Unit No Command Command Check sum code data Command data details 1 0 0 0 0 0 1 1 Multiplic...

Page 34: ...Command Response Status Check sum code data Response data details 0 1 2 3 4 5 Sign Indication offset Writing indication offset setting Command Block 0 0 F W CR Unit No Command Command Check sum code...

Page 35: ...Response data details 0 0 1 Stop output set time Unit 0 1 s Writing cylinder stop output Command Block 0 0 S W CR Unit No Command Command Check sum code data Command data details 0 0 1 Stop output set...

Page 36: ...o Command Response Status Check sum code data Response data details 0 0 Normal output 1 Binary output Writing output type setting Command Block 0 0 O W CR Unit No Command Command Check sum code data C...

Page 37: ...data Response data details 0 0 Phase difference input of A and B phases 1 Individual input of UP DOWN Writing input type setting Command Block 0 0 I W CR Unit No Command Command Check sum code data Co...

Page 38: ...Unit No Command Response Status Check sum code data Response data details 0 0 Backup OFF 1 Backup ON Writing count backup setting Command Block 0 0 B W CR Unit No Command Command Check sum code data...

Page 39: ...atus Check sum code HOLD output release Command Block 0 0 H R CR Unit No Command Check sum code Response Block 0 0 H R CR Unit No Command Status Check sum code Test transmission Command Block 0 0 T S...

Page 40: ...Error status is a text data of 1 byte Command error Response Block 0 0 E E CR Unit No Command Error Check sum code code When there is an error in the command block that has been sent the response bloc...

Page 41: ...D3 Digit of 10 2 Bit3 22 D15 Digit of 101 Bit3 5 D4 Digit of 10 Bit0 23 D16 Digit of 102 Bit0 6 D5 Digit of 10 Bit1 24 D17 Digit of 102 Bit1 7 D6 Digit of 10 Bit2 25 D18 Digit of 102 Bit2 8 D7 Digit...

Page 42: ...input part for photo coupler input Output specification open collector Max 30VDC 15 mA CEU5B BCD output part for NPN output type DC power 5 Output timing ms ms ms ms ms ms Data 1 Data 2 DATA VALID Da...

Page 43: ...e for the encoder specifications 9 Is the pre scale setting proper Set pre scale according to the encoder type and measured object 14 18 Does the frequency of encoder output signals exceed the countin...

Page 44: ...nals for other inputs 12 Control signal input does not become active RESET HOLD BANK Is the counter in count mode Press MODE key to switch the mode to count mode 14 Is the wiring of RS 232C input outp...

Page 45: ...sumed consult the shop or SMC Corporation Check sum trouble with E2 ROM storing the set values z Press any key to delete the memory and return to normal state z Since the set values in the items in wh...

Reviews: