7-1-3. Setting of function mode
Eight items are set in function mode. Items can be switched by UP/ DOWN key during the
items are flashing.
(1) Pre-scale
Display :
Meaning : Function to optionally set the unit per count
Setting
: In model selection, select "CE1" for connecting the series CE1, CE2 or
ML2 and "CEP1" for connecting the series CEP1 to complete pre-scale
setting. For encoders from other manufacturers, select MANUAL and
input multiplication and the unit per count by keys.
(2) Indication offset
Display :
Meaning : Function to set the initial value displayed in reset inputting to an optional
value (with +/
-
setting)
Setting
: Input values by keys.
(3) Cylinder stop output
Display :
Meaning : Cylinder stop output is a signal sent out from S. STOP terminal when
pulse signals from Monosashi-kun (encoder) do not change for a certain
period of time. This output signal provides better timing for reading
preset output and outputs sent to PLC/ PC.
Setting
: Input values by keys. Unit is 0.1 second.
(4) Output type
Display :
Meaning : Switch normal output (using bank function) and binary output (enabling
classification of 31 points).
Setting
: Select normal output "NORMAL" or binary output "BINARY".
(5) Input type
Display :
Meaning : Counter directions can be switched between A/B quadrature input and
UP/ DOWN individual pulse input.
Setting
: Select A/B quadrature input "
±
2PHASE" or individual pulse input
"
±
UPDOWN"
(6) Counts backup
Display :
Meaning : Function to backup counts even when the counter power shut off
Setting
: Select backup active "ON" or inactive "OFF".
(7) RS-232C communication speed
Display :
Meaning : Set communication speed of RS-232C.
Setting
: Select a speed from 1200 bps, 2400 bps, 4800 bps, 9600 bps, or
19200 bps.
-
15
-