Maintenance
Addition of Input Block
Remove screws from End Plate.
Mount attached tie rod.
Connect additional Input Block.
Connect End Plate and tighten removed screws by specified tightening torque. (0.6 Nm)
Exchange of SI unit
Remove screws from End Plate and release connection of each unit.
Replace old SI unit with new one. (Tie rod does not need to be removed.)
Connect End Plate and tighten removed screws by specified tightening torque. (0.6 Nm)
Caution for maintenance
(1) Be sure to turn-off all power supplies.
(2) Be sure that there is no foreign object in any of units.
(3) Be sure that gasket is lined properly.
(4) Be sure that tightening torque is according to specification.
If these items are not kept, it may lead to the breakage of substrate or intrusion of liquid or dust into the
units.
○